Job Aid: Replacing the power supply on the Avaya S8510 Server
62 Job Aids for Field Replacements (FRUs) for the Avaya S8510 Server
Replacing a power supply in the S8510 with dual power
supplies
Note:
Note:
If the S8510 Sever has two power supplies, you do not have to power down the
server to replace the defective, redundant power supply.
Remove the defective power supply
!
WARNING:
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
To remove the defective power supply:
1. Open the cable management arm, if present, to access the rear panel.
2. Identify the defective power supply by looking for the power supply fault indicator (Note 2 in
).
Note:
Note:
The power supply fault indicator is the same on both power supplies.
Figure 18: S8510 power supply LEDs (bay 1 shown)
Figure notes:
1.
Power supply status indicator
3.
AC line status indicator
2.
Power supply fault indicator
Gb 1
Gb 2
hw85pled LAO 050108
1
2
3