Replacing the S8510 server
03-602953 Issue 1 June 2008
17
2. Disconnect the cable assembly from the SAMP (Note 2 in
). Set the cable aside;
you will not re-use the cable but will return it to Avaya with the SAMP.
3. Remove the SAMP card by pulling it gently out of the expansion slot in the riser assembly
(Note 3 in
).
4. .Remove the ribbon cable from the motherboard (Note 4 in
Install the SAMP in the S8510 server
To install the SAMP in the S8510 server, refer to
and using the steps in reverse order:
1. Connect the ribbon portion of the SAMP cable assembly to the motherboard (Note 4 in
).
2. Carefully grasp the SAMP by the outer edges and align it with the opening on the PCI
expansion slot riser assembly. Press the SAMP firmly into the expansion slot (Note 3 in
).
!
CAUTION:
CAUTION:
Make sure the SAMP card is completely seated in the expansion slot before you
apply power to the S8510 server. Incomplete insertion might cause damage to
the system board or to the SAMP card.
3. Connect the other end of the SAMP cable assembly to the SAMP (Note 2 in
).
4. Press the PCI expansion card riser release latches (Note 1 in
) to secure the SAMP
and the riser assembly.
Remove the dual NIC from the S8510 server
To remove the dual NIC from the S8510 server:
1. Press the release latches on the PCI expansion card riser (Note 1 in
).