External Alarm Cabling Specifications
The external alarm relay contacts on the media server have the following characteristics:
●
Normally open contacts for critical, major, and minor alarms
●
Contact current is 2 A maximum•Contact resistance is protected by 0.165 mF/477 W
The external relay contacts have the following dielectric strengths:
●
1500 VAC (50/60 Hz for 1-min) between the coil and the contacts
●
1000 VAC (50/60 Hz for 1-min) between the contacts of the same pole•1000 VAC (50/60
Hz for 1-min) between the contacts of different poles
The external relay contacts can withstand the following surges:
●
2500 V, 2x10 msec between the coil and the contacts, in compliance with Bellcore
standards
●
1500 V, 10x160 msec between the contacts of the same pole, in compliance with FCC Part
68
Pin
Description
Function
Connected to:
Alarm State
Power Fail State
1
No connection
—
—
—
2
External Alarm 2
Input
External Alarm High
—
3
No connection
—
—
—
4
No connection
—
—
—
5
No connection
—
—
—
6
Critical Audible 1
Dry Contact Out
Critical Audible 2
Same
7
Critical Visual 1
Dry Contact Out
Critical Visual 2
Same
8
Minor Audible 1
Dry Contact Out
Minor Audible 2
Open
9
Major Audible 1
Dry Contact Out
Major Audible 2
Open
10
No connection
—
—
—
11
Minor Visual 1
Dry Contact Out
Minor Visual 2
Open
12
Major Visual 1
Dry Contact Out
Major Visual 2
Open
13
No connection
—
—
—
14
No connection
—
—
—
15
External Alarm 1
Input
External Alarm High
—