DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Maintenance
2-17
Maintenance procedure
2
Health of Port Network Connections (PNC)
Depending on the conditions present when the system switched from Normal to
Survive mode, it may be in either Emergency Transfer or Survive mode.
To determine the mode in which the system is operating:
1. Get on overall report on each cabinet’s PNC status (status health)
on both
the Release 9r and the SRP systems
.
Figure 2-9
shows the Release 9r
screen, and
Figure 2-10
shows the SRP screen.
Figure 2-9.
Status health screen (Release 9r)
Figure 2-10.
Status health screen (SRP)
status health SPE A
PNC: A-PNC/auto B-PNC/functional ALARMS: Maj: 2 Min: 2 Wrn: 104
Pwr: comm Sync:loc l Logins:2 BUSYOUT: Trk 0 Stn: 0 Oth: 18
Cab EmTr Mj Mn Wn PNC Cab EmTr Mj Mn Wn PNC Cab EmTr Mj Mn Wn PNC
1 auto- 0| 0|47 up
2 auto- 0| 0|12 up
status health
ALARM SUMMARY CABINET STATUS
Major: 1 Emerg Alarms
Minor: 0 Cab Trans Mj Mn Wn PNC
Warning: 10 1 auto- 0| 0| 5 up
BUSY-OUT SUMMARY 2 auto- 1| 0| 0 dn
Trunks: 0 3 n.a. 0| 0| 0 dn
Stations: 0
Others: 0
PROCESSOR OCCUPANCY STATUS
Static: 1% SM: 4%
CP: 0% Idle: 95%
CRITICAL SYSTEM STATUS
Active SPE: A/auto
Duplicated? SPE:n
SPE Power: commercial
Time Source: local
# Logins: 1