DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Installation
1-21
Administer the Release 9r and SRP
1
6. Repeat steps 2 - 5 for every port on every line circuit pack in the SREPN.
NOTE:
For more information about administering stations, refer to
DEFINITY
Enterprise Communications Server Release 9 Administrator’s Guide.
7. Type save translation and press
Enter
.
Identify and add other circuit packs
For circuit packs other than trunk and line, follow the same guidelines.
1. Display each port on the circuit pack and the equipment type displayed on
the port information screen.
2. Display the equipment on the Release 9r management teminal and add the
information to the SRP system.
3. Type save translation and press
Enter
.
Administering the system features
NOTE:
Customer options available to the SRP are the same as those available on
the existing Release 9r. These are administered by the regional CSA.
Any differences in features from the Release 9r to Release 9si are
experienced in the survivable mode. Refer to the Release 9r and
Release 9si feature administration descriptions for further details.
System administration needs to be added to the SREPN including dialplan,
system features, system maintenance, system security, feature-access-codes,
and so forth. Administer in the same manner as listed above.
1. Display the information on the Release 9r system. For example, type
display feature-access-codes and press
Enter
.
2. Add the information to the SRP system. For example, type change
feature-access-codes and press
Enter
.
3. Type save translation (optional) and press
Enter
.