DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Installation
1-22
Administer the Release 9r and SRP
1
Administering the maintenance parameters
Page 1 of the system-parameters maintenance form contains 2 fields that must be
administered for the abbreviated alarm report.
Figure 1-9
shows the screen with
the
First OSS Telephone Number:
and
Second OSS Telephone
Number:
fields that are administered with offsite notification numbers. The
Abbrev Alarm Report?
fields associated with these numbers must be set to
avoid unnecessary notification calls.
1. Set the two
Abbreviated Alarm Report
fields to y and press
Enter
.
Figure 1-9.
Maintenance-related system parameters screen
change system-parameters maintenance Page 1 of 3 SPE A
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1010101010
First OSS Telephone Number: 9~p5380532 Abbrev Alarm Report? y
Second OSS Telephone Number: 9~p5380533 Abbrev Alarm Report? y
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y Suspension Threshold: 5
Restart Notification? y
Test Remote Access Port? y
CPE Alarm Activation Level: none
Customer Access to INADS Port? y
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 23 : 00 Stop Time: 06 : 00
Daily Maintenance: daily Save Translation: daily
Control Channel Interchange: daily System Clocks Interchange: daily
SPE Interchange: daily