6-4
OVERVIEW: DEFINITY GENERIC 2 WITH UNIVERSAL MODULES
CROSS-CONNECT FIELDS
The DEFINITY Generic 2 with universal modules uses System 75 port board technology and has 500
pairs per carrier and 3 carriers per module. This creates significant differences in wall-field design from
that used in System 85 and DEFINITY Generic 2 with traditional modules. See chapter 7, MDF/IDF
Design: DEFINITY Generic 2 with Universal Modules, for more information on wall-field design for
DEFINITY Generic 2 with universal modules.
TERMINALS AND TERMINAL ADJUNCTS
Physical and functional descriptions for prospective customers, account teams, and others who need
specific information on universal terminals and terminal adjuncts for Generic 2 with universal modules
are listed in About This Document under Related Resources.
CONNECTIVITY
Connectivity for DEFINITY Generic 2 with universal modules is similar to that of System 85 and
DEFINITY Generic 2 with traditional modules. A major difference is the use of unshielded M-F B25A
cables to connect the switch to the male-connectorized cross-connect field wherever possible. Previously
installed systems may require M-M A25D connectorized cables. (See figure 1-1, System 85 and
DEFINITY Generic 2 with Traditional Module Connectivity, for a typical connectivity configuration.)
MAJOR COMPONENTS—SINGLE CARRIER MODULE
The single carrier module (SCM) introduces new cabinetry and equipment into the G2 environment:
●
The SCM is designed as a remote module only and cannot support other remote modules.
●
Each SCM can accommodate one to three single carrier port cabinets to support the port complex.
●
The module control is duplicated in a single carrier.
Cabinet Types
The main components of the SCM are the single carrier module control cabinet (SCMCC) and the single
carrier port cabinet (SCPC). A full, four-cabinet SCM stack contains one SCMCC and three SCPCs.
Содержание 9601
Страница 1: ...555 104 630 Issue 2 June 1991 DEFINITY Communications SystemGeneric 2 and System 85 Wiring ...
Страница 57: ...2 34 MDF IDF DESIGN SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 67: ...3 10 ELECTRICAL PROTECTION SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 73: ...4 6 PORT PACKS DCP REPEATERS SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 85: ...6 6 OVERVIEW DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 102: ...MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES 7 17 Figure 7 8 Combined Trunk and Line Ports ...
Страница 112: ...MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES 7 27 Figure 7 16 Floor Template 24 Inch Tile L472367 ...
Страница 113: ...7 28 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES Figure 7 17 Floor Template Cabinet Lineup L472368 I I ...
Страница 115: ...7 30 MDF lDF DESIGN DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES Figure 7 18 Floor Secured Frame Installation ...
Страница 119: ...7 34 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 123: ...8 4 ELECTRICAL PROTECTION DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 135: ...10 8 INSTALLATION EXAMPLE DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 139: ...11 4 BRI DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 174: ...GL 12 GLOSSARY ...