13-2
FIBER-OPTICS
TABLE 13-1. System 85 and DEFINITY Generic 2 Fiber-Optic Paddleboard Ranges
Distance Limits
Application
Model
62.5 Micron
50 Micron
Generic 2 (traditional module) — as a
Transmitter
982NL
4900 ft
2000 ft
central-location module, a nearby
(1.5 km)
(0.6 km)
remote module, or containing an RMI
Receiver
4900 ft
2000 ft
seining a nearby module
982NK
(1.5 km)
(0.6 km)
Generic 2 (traditional module) — as a
Transmitter
982NN
25,000 ft
12,140 ft
distant remote module or containing an
(7.6 km)
(3.7 km)
RMI serving a distant remote module
Receiver
25,000 ft
12,140 ft
982NM
(7.6 km)
,
(3.7 km)
Generic 2 TMS
4900 ft
2000 ft
— connection to a
Transmitter
982NL
central location or a nearby remote
(1.5 km)
(0.6 km)
module
Receiver
4900 ft
2000 ft
982NK
(1.5 km)
(0.6 km)
Transmitter
982NN
25,000 ft
12,140 ft
Generic 2 TMS — connection to a
(7.6 km)
distant remote module
(3.7 km)
Receiver
982NM
25,000 ft
12,140 ft
(7.6 km)
(3.7 km)
Generic 2 (universal module) — as a
central-location module, a nearby
Transceiver
9823A
4900 ft
2000 ft
remote module, or containing an RMI
(1.5 km)
(0.6 km)
serving a nearby module
Generic 2 (universal module) — as a
distant remote module or containing an
Transceiver
9823B
25,000 ft
12,140 ft
RMI serving a distant remote module
(7.6 km)
(3.7 km)
Transmitter
Z982A
13,000 ft
13,000 ft
System 85 Module — at a central
(4.0 km)
(4.0 km)
location connecting to the TMS
Receiver
Z982B
13,000 ft
13,000 ft
(4.0 km)
(4.0 km)
Transmitter
Z982C
13,000 ft
13,000 ft
System 85 Module — at a remote
(4.0 km)
(4.0 km)
location connecting to the TMS
Receiver
Z982D
13,000 ft
13,000 ft
(4.0 km)
(4.0 km)
13,000 ft
13,000 ft
System 85 Module — at a remote
Transmitter
Z982J
(4.0 km)
(4.0 km)
location connecting to an RMI at the
central locale
Receiver
13,000 ft
13,000 ft
Z982D
(4.0 km)
(4.0 km)
Содержание 9601
Страница 1: ...555 104 630 Issue 2 June 1991 DEFINITY Communications SystemGeneric 2 and System 85 Wiring ...
Страница 57: ...2 34 MDF IDF DESIGN SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 67: ...3 10 ELECTRICAL PROTECTION SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 73: ...4 6 PORT PACKS DCP REPEATERS SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Страница 85: ...6 6 OVERVIEW DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 102: ...MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES 7 17 Figure 7 8 Combined Trunk and Line Ports ...
Страница 112: ...MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES 7 27 Figure 7 16 Floor Template 24 Inch Tile L472367 ...
Страница 113: ...7 28 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES Figure 7 17 Floor Template Cabinet Lineup L472368 I I ...
Страница 115: ...7 30 MDF lDF DESIGN DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES Figure 7 18 Floor Secured Frame Installation ...
Страница 119: ...7 34 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 123: ...8 4 ELECTRICAL PROTECTION DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 135: ...10 8 INSTALLATION EXAMPLE DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 139: ...11 4 BRI DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Страница 174: ...GL 12 GLOSSARY ...