- 36 -
light is twinkling
:
a)TW
≤
-6
℃
and continuously last for 2minutes
;
b)The accumulated operation time of the compressor is over than 50 minutes, the interval
time between defrosting process is 50 minutes(the accumulated time shall be recalculated if
power off or remote control off ), the continuous working time of the compressor is over 5
minutes.
Once the defrosting process starts, the compressor, the indoor fan and outdoor fan turn off,
and the four-way valve turns off after 30 seconds, and after another 15 seconds the
compressor turns on and starts the defrosting process.
②
The defrosting process ending condition
:(
The defrosting process will quit if one of the
below conditions to be satisfied
)
a) Outdoor coil
≥
12
℃;
b) Defrosting process last for 12minutes
;
c) The defrosting process quits once change modes or air-conditioner turns off by remote
control.
After the defrosting process, the compressor turns off and the outdoor fan turns on; After 55
seconds, the four-way valve turns on; after another 5 seconds, the compressor turns on; the
air-conditioner resume the normal heating process, the indoor fan runs in the mode of
anti-cold wind.
⑻
Auxiliary electric heating function
①
When heating mode working normally, e.g. the compressor starts and the outdoor fan runs
and the four-way valve is electrified and the indoor fan starts, the electric heating starts if
satisfying the below conditions:
A
、
TE < 48
℃;
B
、
TA < 22
℃;
C
、
TS – TA
≥
3
℃;
D
、
The compressor runs continuously for 4 minutes with the heating mode;
②
The auxiliary electric heating quit operation if satisfying one of the below conditions
:
A
、
TA > 22
℃;
B
、
TS – TA < 2
℃;
C
、
TE > 52
℃;
③
If anyone of the compressor, four-way valve and indoor fan doesn’t work or fault feedback
from the indoor fan, the auxiliary electric heating quit operation
;
The au
④
xiliary electric heating may be allowed to restart after 1 minutes rest if the auxiliary
electric heating quit during the operation process of the compressor.
⑼
Sleeping control function
The sleeping function is valid during the automatic, cooling, dehumidifying and heating
process. The indoor fan runs at low fan speed during sleeping mode, and the sleeping
indication light on;
After turning into the sleeping process by pressing down the button of “sleeping” on the
remote controller, to the Cooling process, the setting temperature rises by 1
℃
automatically
one hour later; to the Heating process, the setting temperature falls by 2
℃
automatically one
hour later. After another 1 hour, the setting temperature of the Cooling process raises another
1
℃
, and the one of the Heating process falls another 2
℃
. The sleeping process lasts 7 hours
until air-conditioner turns off.
During the sleeping process, the mode switching operation is allowed and workable, but it will
Содержание ASW-H09A4/EAR1-dw
Страница 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Страница 6: ... 4 Remote Controller Instructions ...
Страница 7: ... 5 ...
Страница 8: ... 6 ...
Страница 9: ... 7 ...
Страница 10: ... 8 ...
Страница 11: ... 9 ...
Страница 12: ... 10 ...
Страница 13: ... 11 ...
Страница 14: ... 12 ...
Страница 20: ... 18 2 18000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 21: ... 19 3 24000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 47: ... 45 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 48: ... 46 ...
Страница 53: ... 51 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Страница 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Страница 76: ......