- 22 -
①
When TA - TS
≥
1
℃,
after the compressor meet the 3 minutes delay protection, the
compressor and the outdoor fan start running;
②
When TA = TS
,
maintain the previous status;
③
When TA - TS
≤
-1
℃,
after the compressor meet the 3 minutes protection condition, the
compressor and the outdoor fan turn off;
④
The setting wind speed can be adjusted by the remote control during the ongoing cooling
process, and the interior fan still retains working;
⑤
When it is given the condition
「
TE
≤
2
℃」
(Tc=temperature of the indoor coil),which lasts for
10 seconds , meanwhile compressor runs for more than 30 seconds, the outdoor fan will be
turned off ; When it is given the condition
「
TE
≤
0
℃」
(TE=temperature of the indoor coil),which
lasts for 10 seconds , meanwhile compressor runs for more than 5 minutes, compressor will
be turned off and indoor fan runs according to the set speed ; When it is given the condition
「
TE
≥
7
℃」
(TE=temperature of the indoor coil), system will quit aforesaid protective mode.
⑥
This mode includes the functions of timing, sleeping, auto-restart (optional), negative ion
(optional), I feel
(
optional
)
;
⑦
When the cooling ongoing
,
the button of the “Swing” can control the swing and stop of the
horizontal air-blade;
⑧
Automatic wind-speed control
:
TA - TS
≥
3
℃,
wind-speed works in high wind;
TS +1
℃
≤
TA
<
TS +3
℃,
wind-speed works in middle wind;
TA – TS
<
1
℃,
wind-speed works in low wind;
Without 3 minutes delay when the wind speed turns from the high wind from the low wind,
otherwise with 3 minutes delay;
⑨
Being initially electrified, the compressor doesn’t have the 3 minutes extension/delay
protection, the outdoor fan starts after 2 seconds of the compressor’s start; TS
>
TA set by the
remote control, the compressor turns off immediately with no need of 3 minutes delay
protection;
(5)Dehumidification mode
①
The four-way valve always turns off when the dehumidification mode is ongoing. The
control range of the temperature is: 16
℃
- 32
℃
.
②
Under the dehumidification mode, after the 3 minutes protection conditions being meet
satisfactorily, the performance of the compressor and the outdoor fan is as following:
a)TA
≥
TS+2
℃,
the compressor and the outdoor fan works continuously, the wind speed
retains the setting wind speed;
b)TS
≤
TA < TS+2
℃,
the compressor and the outdoor fan runs for 10minutes and stops for
6minutes
,
The indoor fan turns off during the compressor’s 3 minutes stopping period and
keeps on working in breeze mode under other conditions;
c)TA < TS
,
the compressor and the outdoor fan stop working, and the indoor fan start to work
in breeze mode after stopping for 3 minutes
;
Automatic wind-speed control
:
TA - TS
≥
5
℃,
the wind speed is on high wind;
TS +3
℃
≤
TA
<
TS +5
℃,
the wind speed is on middle wind;
TS +2
℃
≤
TA
<
TS +3
℃,
the wind speed is on low wind;
TS
≤
TA
<
TS +2
℃,
the wind speed is on fitful breeze;
TA
<
TS
,
the indoor fan is off during the 3 minutes delay of the compressor, and 3 minutes
Содержание ASW-H09A4/EAR1-dw
Страница 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Страница 6: ... 4 Remote Controller Instructions ...
Страница 7: ... 5 ...
Страница 8: ... 6 ...
Страница 9: ... 7 ...
Страница 10: ... 8 ...
Страница 11: ... 9 ...
Страница 12: ... 10 ...
Страница 13: ... 11 ...
Страница 14: ... 12 ...
Страница 20: ... 18 2 18000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 21: ... 19 3 24000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 47: ... 45 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 48: ... 46 ...
Страница 53: ... 51 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Страница 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Страница 76: ......