(3)Troubleshooting Guide Specially
1.H series & E series (For LED display
:
Timer indicator (Yellow lamp) flashes)
:
Trouble source
Displayed phenomenon
Display priority class
PG motor of indoor unit feedback
abnormity
Sparkle
4
times per
8
seconds
1
Temperature sensor of air intake
abnormity
Sparkle
1
time per
8
seconds
2
Temperature sensor of indoor unit
coil abnormity
Sparkle
2
times per
8
seconds
3
Temperature sensor of outdoor unit
coil abnormity
Sparkle
1
time per
1
second
4
2.H series & E series (For Digital display)
:
Trouble source
Displayed phenomenon
Display priority class
PG motor of indoor unit feedback
abnormity
E4
1
Temperature sensor of air intake
abnormity
E1
2
Temperature sensor of indoor unit
coil abnormity
E3
3
Temperature sensor of outdoor unit
coil abnormity
E2
4
Communication abnormity between
outdoor unit and indoor unit
E5
5
Note:
1. “Sparkle 1 time per 8 seconds” indicated on LED display model is the same as “E1”
displayed on Digital display model.
2. “Sparkle 1 time per 1 seconds” indicated on LED display model is the same as “E2”
displayed
on Digital display model.
3. “Sparkle 2 times per 8 seconds” indicated on LED display model is the same as “E3”
displayed on Digital display model.
4.“Sparkle 4 times per 8 seconds” indicated on LED display model is the same as “E4”
displayed on Digital display model.
Explanations as follows:
1. E1 and E3 is the problem of temperature sensor in indoor unit. Two temperature sensors
are in indoor unit. One is made of plastic material and another one is made of copper material.
If the plastic sensor is damaged, for example, its resistance value deviates from its original
value greatly, E1 malfunction indication will spear. Or, this sensor’s signal cable is broken and
no signal will be received from this sensor, E1 will appear as well. So, when E1 appear,
maintenance man should test its resistance value and its cable connection with PCB.
2. As said above, there is a copper sensor which used to detect the outlet temperature of
evaporator. If the sensor’s cable broken or sensor’s resistance deviating from its original
correct value, E3 will appear. Check its value and its cable connection with PCB.
Содержание ASW-H09A4/EAR1-dw
Страница 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Страница 6: ... 4 Remote Controller Instructions ...
Страница 7: ... 5 ...
Страница 8: ... 6 ...
Страница 9: ... 7 ...
Страница 10: ... 8 ...
Страница 11: ... 9 ...
Страница 12: ... 10 ...
Страница 13: ... 11 ...
Страница 14: ... 12 ...
Страница 20: ... 18 2 18000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 21: ... 19 3 24000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 47: ... 45 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 48: ... 46 ...
Страница 53: ... 51 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Страница 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Страница 76: ......