- 13 -
Brief Introduction Of Installation
The installation of air-conditioner should meet with the “Installation Instruction”. The machine
must be installed correctly by professional technicians according to the “Installation
Instruction”.
(1) Guide to customer
①
The customer should provide a suitable power supply source, its voltage should be in the
range of 90-110% of its rated voltage.
②
The power supply circuit should have MCB leakage protection. The capacity should be
more than 1.5 times of the maximum current.
③
Must use independent circuit and suitable grounding socket matching with the plug of
air-conditioner.
④
The wiring must be installed by qualified electrician according to the electrical safety
requirements.
⑤
The air-conditioner must be well grounded, the switch of the main power of air-conditioner
must be reliably grounded.
⑥
The power supply wire, must be changed by qualified electrician.
(2) Installation Instruction
1. Installation order
Selection of the installation position Installing the air-conditioner
Expelling the air in the pipes and the indoor unit Connecting the pipes and wires
Testing
2. Selection of the installation position
Indoor Unit:
①
There is no heating and steaming source nearby.
②
No obstacles for installation position from nearby.
③
Keep good air circulation.
④
Convenient to adopt measures to reduce noises.
⑤
Don’t install them near the doorway.
⑥
Make sure to have the distance specified in the picture between the ceiling, wall, furniture
and other obstacles.
⑦
2 meters high above the floor.
Outdoor Unit:
①
In case that you put up a canopy to protect it from rains and sunrays, pay attention not to
cause any obstacles for the heating dispersion for the condenser.
②
Don’t keep animals or plants near the installation location for the hot air from the outdoor
unit will affect them.
③
Make sure to have the distance specified in the picture between ceiling, wall, furniture and
other obstacles.
④
Stay away from heating source and inflammable air.
⑤
The installation base and supporting frame should be strong and secure. The machine
should be at a level surface.
Содержание ASW-H09A4/EAR1-dw
Страница 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Страница 6: ... 4 Remote Controller Instructions ...
Страница 7: ... 5 ...
Страница 8: ... 6 ...
Страница 9: ... 7 ...
Страница 10: ... 8 ...
Страница 11: ... 9 ...
Страница 12: ... 10 ...
Страница 13: ... 11 ...
Страница 14: ... 12 ...
Страница 20: ... 18 2 18000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 21: ... 19 3 24000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 47: ... 45 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 48: ... 46 ...
Страница 53: ... 51 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Страница 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Страница 76: ......