- 14 -
3. Installation
Outdoor Unit:
①
The outdoor unit must be firmly fixed to avoid falling in
strong wind.
②
Install on the cement base as in the drawing.
③
If it is installed at seaside or at a place high above the
ground and with strong wind, the AC should be installed
against the wall to ensure the normal operation of the fan
and the blocking plate should be used.
④
If it is an overhanging installation, the structure of the
mounting wall should be made of solid, cement or materials
with equivalent strength, and of sufficient support capacity.
Otherwise, measures such as reinforcement, support or
vibration damping should be adopted.
Indoor Unit
①
First make changes to wall and make sure that is hard
and secure. Using four “+” type screws to fasten the
installation board onto the wall. Keep it level in horizontal
direction and perpendicular in vertical direction.
Otherwise it might cause water drips when air-conditioner
is running in cooling operation.
②
Drill 70mm diameter pipe hole at the left lower or right
lower side of the installation board. The hole shall slant
outward slightly.
③
Hang the indoor unit to the oard and make sure the
machine is in the middle of the board.
④
Push the machine towards the left lower and right lower
side of the installation board until the hangers enter tightly
into the grooves (it produces “click” sound)
4. Check the water discharge
(1)Take off the frame from the unit cover.
Take off the front frame for maintenance according to the
following steps:
①
As shown in the picture on the right, take off two covers
from the front frame and then unfasten two fixture screws.
②
Pull the front frame towards yourself and take it off.
To put the front frame back, reverse the steps.
You should check whether the front frame is firmly fixed
into the fixture groove on the top.
(2)Check the water discharge
①
Pour a cup of water into groove.
②
Check whether the water flow through the water
discharge hole.
Содержание ASW-H09A4/EAR1-dw
Страница 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Страница 6: ... 4 Remote Controller Instructions ...
Страница 7: ... 5 ...
Страница 8: ... 6 ...
Страница 9: ... 7 ...
Страница 10: ... 8 ...
Страница 11: ... 9 ...
Страница 12: ... 10 ...
Страница 13: ... 11 ...
Страница 14: ... 12 ...
Страница 20: ... 18 2 18000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 21: ... 19 3 24000 BTU 1 Indoor Unit Cooling Only Cooling Heating 2 Outdoor Unit Cooling Only Cooling Heating ...
Страница 47: ... 45 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 48: ... 46 ...
Страница 53: ... 51 7 Remote Control Can Not Work Trouble shooting procedure 8 The Failure Analysis of the Main Parts ...
Страница 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Страница 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Страница 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Страница 76: ......