12 Driver Function
116
© Copyright Reserved Autonics Co., Ltd.
Example of S-curve acceleration/deceleration parameter setting (full S-curve
acceleration/deceleration)
This example is S-curve acceleration with start drive speed 0 pps and max. drive speed 40
kpps during 0.4 sec. For full S-curve acceleration drive without trapezoidal zone, set the “S
Curve Time” as 0.2 sec which is half of acceleration time.
1st
Start drive speed as 0 is ignored.
2nd
This is full S-curve acceleration.
During 0.2 sec, it drives trapezoidal acceleration up to 20,000pps.
3rd
At the left 0.2 sec, it drives trapezoidal deceleration up to 40,000pps.
For each setting value of parameters and descriptions, refer to the below table.
Parameter
Setting
value
Description
Acceleration Time
4000 msec
For S-curve drive, acceleration/
deceleration time should be same.
Deceleration Time
4000 msec
S Curve Time (S-curve
acceleration/deceleration time)
2000 msec
For S-curve drive without trapezoidal,
it should be set the half of
acceleration/deceleration time.
Start Speed (start drive speed)
0 pps
-
Max Speed (max. drive speed)
40000 pps
-
Содержание AiCA Series
Страница 2: ...ii Copyright Reserved Autonics Co Ltd ...
Страница 35: ...6 Characteristics Copyright Reserved Autonics Co Ltd 35 ...
Страница 70: ...10 Drive 70 Copyright Reserved Autonics Co Ltd ...
Страница 72: ...10 Drive 72 Copyright Reserved Autonics Co Ltd ...
Страница 74: ...10 Drive 74 Copyright Reserved Autonics Co Ltd ...
Страница 76: ...10 Drive 76 Copyright Reserved Autonics Co Ltd ...
Страница 84: ...10 Drive 84 Copyright Reserved Autonics Co Ltd ...
Страница 130: ...14 Troubleshooting 130 Copyright Reserved Autonics Co Ltd ...
Страница 131: ... Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice ...