7 Driver Unit Descriptions
38
© Copyright Reserved Autonics Co., Ltd.
7.2
Switches
7.2.1
ID Sel
: Communication ID Setting Switch
Set Node ID of the driver.
Depending on the ID setting of the ID/TERM switch, it is possible to connect max. 31-axis.
Setting
switch
Setting
ID
Setting
ID
ID OFF
ID ON
ID OFF
ID ON
ID Sel
0
Disable
16
8
8
24
1
1
17
9
9
25
2
2
18
A
10
26
3
3
19
B
11
27
4
4
20
C
12
28
5
5
21
D
13
29
6
6
22
E
14
30
7
7
23
F
15
31
7.2.2
ID, TERM
: Communication ID Setting/Terminating Resistance DIP Switch
Set Node ID of the driver.
Set to use terminating resistance.
No. Function
Switch position
ON
OFF
1
ID setting
ID: 16 to 31
ID: 1 to 15
2
Terminating
resistance
Use terminating
resistance (120
Ω
)
Do not use terminating
resistance
Содержание AiCA Series
Страница 2: ...ii Copyright Reserved Autonics Co Ltd ...
Страница 35: ...6 Characteristics Copyright Reserved Autonics Co Ltd 35 ...
Страница 70: ...10 Drive 70 Copyright Reserved Autonics Co Ltd ...
Страница 72: ...10 Drive 72 Copyright Reserved Autonics Co Ltd ...
Страница 74: ...10 Drive 74 Copyright Reserved Autonics Co Ltd ...
Страница 76: ...10 Drive 76 Copyright Reserved Autonics Co Ltd ...
Страница 84: ...10 Drive 84 Copyright Reserved Autonics Co Ltd ...
Страница 130: ...14 Troubleshooting 130 Copyright Reserved Autonics Co Ltd ...
Страница 131: ... Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice ...