9 Control Input/Output
© Copyright Reserved Autonics Co., Ltd.
49
9.1.2.1
Reset
When driver is reset, it operates same as resupplying the power.
The parameter which is saved at atMotion is not reset.
During motor driving, it stops immediately and the driver is reset.
9.1.2.2
Start
It starts drive as the set mode; index mode or program mode.
When it stops by stop instruction during driving with program mode, supplying start
input, it starts drive from the first step.
When it pauses by pause instruction during driving with program mode, supplying start
input, it starts drive from the next step of the paused one.
Содержание AiCA Series