12 Driver Function
118
© Copyright Reserved Autonics Co., Ltd.
12.2
Other Functions
12.2.1
Limit Operation
Hardware and software limits can be used to stop drive.
Hardware limit
Install a limit sensor to the machine to monitor system operation directly.
Connect Nlmt+/- (Pin19, 20) at I/O connector (CN3).
Set Instant (instant stop) / Slow (deceleration stop) at Limit Stop Mode (limit Stop
mode) of Operation Mode.
Software limit
Unlike the input of hardware limit signal by external sensor, this limit function is set
using internal position data.
To operate software limit, set software limit (software limit) as Enable.
High and low limit values can be set each axis separately at ±software limit (±software
limit) parameter.
Operation Mode
Setting value Parameter
Setting value
Software Limit
Enable
+Software Limit
100,000
-Software Limit
-50,000
When the setting value is as above, the position value operates among -50,000 to
100,000 range. When it is out of the range, the drive decelerates and stops.
Hardware limit operates independently regardless of the software limit settings, and
only hardware limit except limit home search is operated during home search.
Содержание AiCA Series
Страница 2: ...ii Copyright Reserved Autonics Co Ltd ...
Страница 35: ...6 Characteristics Copyright Reserved Autonics Co Ltd 35 ...
Страница 70: ...10 Drive 70 Copyright Reserved Autonics Co Ltd ...
Страница 72: ...10 Drive 72 Copyright Reserved Autonics Co Ltd ...
Страница 74: ...10 Drive 74 Copyright Reserved Autonics Co Ltd ...
Страница 76: ...10 Drive 76 Copyright Reserved Autonics Co Ltd ...
Страница 84: ...10 Drive 84 Copyright Reserved Autonics Co Ltd ...
Страница 130: ...14 Troubleshooting 130 Copyright Reserved Autonics Co Ltd ...
Страница 131: ... Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice ...