26
NeoSlider
TM
- Sliding Gate Opener NES-24V3
Owner Installation Instructions
having to disconnect the Battery Backup / Solar system.
Menu 7.11 Password Protection
The password feature enables all parameters and configuration settings to be protected unless a password is entered.
When this feature is turned on, the user is requested to enter the desired password to be used. The password protection
feature has a time-out that expires after 60 seconds of inactivity. Alternatively, the user may log out manually by pressing
exit when the main screen is displayed.
Menu 7.12 Transmitter Grouping
The transmitter store number display format can be changed to show a grouped format. When grouping is selected,
instead of displaying the store location as a number between 1 and 511, it will display as ##$ where ## is the group
number and $ is a character a,b,c,d,e,f,g or h which indicates the group member.
Menu 7.13 Output1 Mode
AUX output can be selected to be driven by:
i. Lock Drive:
Lock output can be programmed for both hold and pulse mode. The operation of the lock can be
programmed to activate prior to the gate and behave differently on open cycles to that on close cycle.
ii. Light Drive:
a light relay module can be connected on the console between V+ and OUT2 terminal which will turn
the courtesy light on and off.
iii. 3 Wire Safety Beam 0V:
.
iv. Not Used
Menu 7.14 Output2 Mode
AUX output can be selected to be driven by:
i. Lock Drive:
Lock output can be programmed for both hold and pulse mode. The operation of the lock can be
programmed to activate prior to the gate and behave differently on open cycles to that on close cycle.
ii. Light Drive:
a light relay module can be connected on the console between V+ and OUT2 terminal which will turn
the courtesy light on and off.
iii. 3 Wire Safety Beam 0V:
iv. Not Used
Menu 7.15 Fault, Auto Reset
When selected, the controller will reset any fault automatically.
Menu 7.16 Safety Beam Failure Emergency Close Mode (SBFEC)
When a safety beam prevents movement due to any reason other than a ‘real’ obstruction, the user can secure their
property by pressing and holding a button on the remote control or OSC on the console. The button must be held active
for more than five seconds to activate this mode and hold the button for the entire duration of close cycle.
D - Control Board Adjustments