Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-24V3
17
Fig 14.1
Fig 14.2
Fig 14.3
WARNING! The Auto-Close function is not
available unless Safety Beam is installed.
15.1 Setting Up Standard Auto-Close
Menu 3. Auto-Close Times
Auto-Close mode is a function that automatically closes
the gate a preset time after the Safety Beam recognise that
a vehicle has left the gateway. The Auto-Close timer only
starts after the Safety Beam path is broken and the Auto-
Close timer has been set. If the Safety Beam path is not
broken, the gate will remain open until the path is broken.
If the opener incurs a physical obstruction (i.e. not from the
Safety Beam) while closing, the gate will re-open and not
Auto-Close until the Safety Beam path is broken again.
Menu 3.1 Auto-Close
This mode is selected by entering a non-zero time for the
STD Auto-Close parameter. When selected, the gate will
Auto-Close after being fully opened (except when the gate
has reversed to the open position after a motor obstruction
or overload unless A/C after open and/or close Obstruction
are selected). Countdown is suspended by: S.B., OPN or
SWP input being active. The countdown is aborted if the
STP input is activated. If the gate is already open and the
OPN or the SWP input is activated, then the countdown
will start.
15.2 Safety Beam Triggered Auto Close
Menu 3.2 (SB AC Trig)
This mode is selected by entering a non-zero time for the
“Safety Beam Auto-Close” parameter. This mode is used
to Auto-Close the gate but only after an object has passed
through the gateway and has triggered the Safety Beam
input. Any Safety Beam or combination of Safety Beams
can be configured to activate Safety Beam Auto-Close
mode and combinations are
:
One Beam only
i. Safety Beam 1
ii. Safety Beam 2
Either Beam
i. Safety Beam 1 or Safety Beam 2
Combination
ii. Safety Beam 1 and Safety Beam 2
iii. Safety Beam 2 then Safety Beam 1
NOTE:
The swipe input can be used to clear the Safety
Beam triggered status so that the Safety Beam input must
be activated again before the countdown will start. As with
the other Safety Beam modes, the STP input will abort
countdown and the OPN and SWP inputs will restart the
countdown if the gate is OPEN.
15. Auto-Close Mode
15.3 Pedestrian Auto-Close
Menu 3.3 Safety Beam Auto-Close
This mode is selected by entering a non-zero time for the
“Safety Beam Auto-Close” parameter. This mode is used
to Auto-Close the gate but only after an object has passed
through the gateway and has triggered the Safety Beam
input
Menu 3.4 Pedestrian Auto-Close
This mode is selected by entering a non-zero time for
the “Ped’n A/C” parameter. When selected, the gate will
Auto-Close after being opened for pedestrian access
unless it was following a reverse from an obstruction.
Menu 3.5 (Safety Beam) Pedestrian Triggered Auto-Close
This mode is selected by entering a non-zero time for
the “Safety Beam Pedestrian Auto-Close” parameter.
Any Safety Beam or combination of Safety Beams can be
configured to activate Safety Beam Auto-Close mode and
combinations are
:
One Beam only
iv. Safety Beam 1
v. Safety Beam 2
Either Beam
i. Safety Beam 1 or Safety Beam 2
Combination
ii. Safety Beam 1 and Safety Beam 2
iii. Safety Beam 2 then Safety Beam 1
Menu 3.6 (Safety Beam) Pedestrian Auto-Close
This mode is selected by entering a non-zero time for
the “Ped’n A/C” parameter. When selected, the gate will
Auto-Close after being opened for pedestrian access but
only after an object has passed through the gateway and
has triggered the Safety Beam input.
15.4 Auto-Close After Obstruction
Two parameters are provided to enable the Auto-Close
feature to be activated after obstructions and power up.
Normally the Auto-Close feature is not enabled after
obstructions for safety reasons. Safety Beams must be
used for these features to be activated.
Menu 3.7
This mode enables the Auto-Close feature to be activated
when a close obstruction occurs (requires Safety Beams).
Menu 3.8
This mode enables the Auto-Close feature to be activated
when an open obstruction occurs.
Menu 3.9
This mode enables Auto-Close feature after power up.