The standard operation of the opener can be altered by editing various parameters. This section describes the parameters
and the effect they have. Use the VIEWING AND EDITING PARAMETER PROCEDURE (Appendix B) to make changes.
Menu 6. Motor settings
Motor speed
The maximum speed the motors run at is controlled by the MOTOR FULL SPEED VOLTAGE parameter. The default
value is the maximum recommended for normal operation. If however the gates move too quickly for a particular
installation, the voltage can be reduced to make the motors run slower.
NOTE:
Altering these parameters will cause
the travel limits to be cleared.
Menu 7. Operating Modes
Menu 7.1 First (SB1) Safety Beam Type
Select what type of Safety Beam (2 WIRE or 3 WIRE). 2 WIRE is default.
Menu 7.2 Second (SB2) Safety Beam Type
Select what type of Safety Beam (2 WIRE or 3 WIRE). 2 WIRE is default.
Menu 7.3 First (SB1) Safety Beam Response Mode
The Safety Beams input can be configured to respond in one of eight modes.
i. Not Used
ii. Close to Reverse
In this mode, the Safety Beam input has no effect when opening but will cause the gate
to reverse if activated when closing.
iii. Close to Stop
In this mode, the Safety Beam input has no effect when opening but will stop the gate when
closing.
iv. Open and Close to Stop
In this mode, all cycles are prevented from being completed or initiated when the
Safety Beam input is active.
v. Open input
In this mode, open cycle is initiated when the Safety Beam is activated.
vi. Swipe input
In this mode, open cycle is initiated when the Safety Beam is activated.
vii. Close input
In this mode, close cycle is initiated when the Safety Beam is activated.
viii. Ped input
In this mode, ped cycle is initiated when the Safety Beam is activated.
ix. Disabled
In this mode, Safety Beam is disabled.
Menu 7.4 Second Safety Beam (SB2) Response Mode
Same as above menu 7.3
Menu 7.5 PED Input Function
If GPI or Fire Input is selected as PED then these inputs can be configured to a SWIPE type input for pedestrian access. This provides full
functionality with the Safety Beam Triggered Pedestrian Auto-Close function.
Menu 7.6 Open (Opn) Input
(Activated by OPN terminal with N/O switch, by transmitter button with OPN function assigned or by console’s UP button) Activating the
OPN input will cause the gate to open. Holding the input will prevent closing.
Menu 7.7 Stop (STP) Input
(Activated by STP terminal with N/O switch, by transmitter button with STP function assigned or by console’s EXIT button)
Activating the STP input while the gate is moving will cause the gate to be stopped. If the STP terminal is held it will
prevent the gate from being moved.
Menu 7.8 Remote Code
The controller supports the Remote Code Set feature. This parameter can be used to disable the feature for security or transmitter
management reasons.
Menu 7.9 Vacation Mode
Vacation mode blocks all but one designated remote transmitter from activating the NeoSlider™. The mode is activated
by pressing a transmitter button with the VAC function assigned until the console displays that vacation mode is enabled
(approx. 5 secs). When activated, any transmitter button which is assigned VAC will be ignored. To turn Vacation mode off,
press a transmitter button with the VAC function assigned. Vacation mode can also be turned on or off manually by editing
the VACATION MODE parameter.
Menu 7.10 Battery / Solar Mode
The controller can be instructed to turn off the Battery Backup / Solar facilities so that the control board can be shut down without