UL
325
P
RIMARY AND
S
ECONDARY
E
NTRAPMENT
P
ROTECTION
SAFETY INSTRUCTIONS REGARDING PRIMARY & SECONDARY
ENTRAPMENT PROTECTION.
THIS UNIT IS PROVIDED WITH TWO MEANS OF ENTRAPMENT PROTECTION. (SEE UL-325 SECTION 30)
(A GATE OPERATOR SHALL PROVIDE 1
PRIMARY
(INHERENT) AND 1
SECONDARY
ENTRAPMENT
FEATURE).
PRIMARY
: TYPE A – INHERENT ENTRAPMENT SENSING SYSTEMS
THE VPL-24 WILL REVERSE DIRECTION WHEN THE INHERENT TYPE A DEVICE SENSES AN
OBSTRUCTION.
SECONDARY
: TYPE B1 – PROVISION FOR CONNECTION OF A NON-CONTACT SENSOR
(PHOTOELECTRIC OR THE EQUIVALENT.
(NOTE: UNIT SHIPS WITH S1-6 ON & S1-8 OFF. DO NOT CHANGE THESE SETTINGS)
PRIMARY PROTECTION
DESIGNATED TYPE A INHERENT PROTECTION. UNIT WILL REVERSE DIRECTION
WHEN AN OBSTRUCTION IS SENSED WHILE MOVING IN EITHER DIRECTION. SENSITIVITY IS ADJUSTED
ARE IRD1 ON CONTROL BOARD. WHILE CLOSING IF A OBSTRUCTION IS SENSED BY THE PRIMARY
INHERENT SENSOR, THE GATE WILL REVERSE AND OPEN TO THE FULL OPEN POSITION. THE GATE
WILL REMAIN THERE UNTIL A CLOSE COMMAND IS RECEIVED OR WILL CLOSE BY TIMER AFTER NEW
INPUT IS RECEIVED. IN ORDER FOR THE GATE TO CLOSE BY TIMER (IF ACTIVATED) A NEW INPUT ON
TERMINALS J5 1-8 MUST BE GIVEN. IF AN INPUT STILL PRESENT WHEN THE GATE REACHED THE FULL
OPEN POSITION, THIS INPUT WILL NEED TO BE RENEWED OR REMOVED AND ANOTHER INPUT GIVEN
BEFORE THE CLOSE TIMER WILL CLOSE THE GATE.
ENTRAPMENT ALARM
WILL ACTIVATE UPON THE PRIMARY INHERENT SENSOR SENSING A SECOND
OBSTRUCTION BEFORE REACHING A LIMIT SWITCH. ONCE ACTIVATED, GATE WILL REMAIN AT REST
ALARM WILL SOUND. THIS CONDITION CAN ONLY BE CLEARED BY AN INPUT APPLIED TO J5#4. THE
WIRING USED TO RESET THE OPERATOR MUST BE IN THE LINE OF SIGHT AND MUST BE AN
“INTENDED” RESET. ACCESS CONTROL DEVICES OF ANY KIND THAT REQUIRE AN INTENDED (ON
PURPOSE) ACTIVATION MAY BE USED FOR THIS RESET. DEVICES THAT WILL CAUSE AN INCIDENTAL
RESET (VEHICLE DETECTORS, PROBES, TIMERS, MOTION SENSORS, PHOTO BEAMS, ECT…) MUST
NOT
BE USED
.
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY RESULT IN SERIOUS
INJURY OR DEATH
.
1.800.944.4283 AutoGate Technical Support
6
IMPORTANT!
The secondary entrapment device
must comply with UL 325, 4
th
edition effective criteria of March 1,
2000.
Содержание VPL-24/UL
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......