background image

TO THE NEW OWNER

 

Congratulations! You are the owner of a state of the art Archer High Efficiency Gas Log Space Heater. 
 
This  appliance  has  been  designed  to  provide  you  with  all  the  warmth  and  charm  of  a  wood  fire  at  the  flick  of  a 
switch. The Archer Gas Log Space Heater promises to provide you with the highest economy, heat output, comfort 
and security. 
 
NOTE: AURORA WARRANTY PROGRAM 
Please note to qualify for the Aurora Warranty Program, you need to fill out the warranty registration form, and have 
your qualified installer fill out the Installation Commissioning Report. Both documents must be returned promptly to 
Aurora Climate Systems. 
 
Under new government legislation, you also need to obtain from your qualified installer, a Certificate of Compliance 
for the guarantee of the installation. 
 
Please note, that Aurora Climate Systems will not accept responsibility for faults with the appliance caused through 
installation  faults.  We  therefore  strongly  recommend  that  you  return  to  Aurora  Climate  Systems  the  Installation 
Commissioning  Report  and  obtain  a  Certificate  of  Compliance  from  your  qualified  installer  for  your  protection.  
Failure to do so can void your warranty. 
 
Please  take  a  moment  now  to  acquaint  yourself  with  the  instructions  and  many  features  of  your  Archer  High  
Efficiency Gas Log Space Heater. 
 
Warranty - Installation - Service 
 
(Listing and Code Approvals) 
This appliance has been tested in accordance with SAI Global to code AS4553 Test Approval No. GSCS20025, and 
has been certified to the Electrical AS3100 standard. 
 
Check with your local council’s building department to ensure compliance with local codes, including the need for 
permits and follow up inspections. Or if you wish clarification of the instructions contained in this manual, please 
contact Aurora Climate Systems on telephone (03) 9795 8895 or facsimile (03) 9701 2088. 
 

Note: 

As  the  Archer  Gas  Log  Space  Heater  you  have  purchased  is  a  high  tech,  high  efficiency   

 

appliance, 

we wish to advise that your appliance should at all times only be installed by a licensed Gas

 

Fitter / Installer for the installation and service of the Archer Gas Log Space Heater. 

 
 

At  no  time  should  this  appliance  be  installed  outside  the  installation  guide  lines  contained  in  the  

 

Installation Manual, or by a non qualified gas fitter / installer. To do so will void the warranty. 

 
 

It is policy of Aurora Climate Systems that should a fault develop in the Archer Gas Log Space  Heater  during 

 

its warranty period, Aurora will repair the appliance in these circumstances. However we wish to advise that  

 

should the Archer Gas Log Space Heater develop a fault in its operation  because the product was not installed 

 

in  accordance  with  the  manufacturer’s  guidelines  and  instructions,  or  if  the  product  was  not  installed  

 

correctly by a licensed gas fitter / installer or lack of operating knowledge of the appliance by the customer 

 

causing appliance failure, then a service charge will apply. 

 
 

In such cases, where attendance is required by Aurora Service Personnel to correct faults in the product which 

 

are not directly related to the product and / or parts failure but are the result of improper installation and lack 

 

of  operating  knowledge  of  the  appliance,  Aurora  Climate  Systems  will  charge  the  purchaser  of  the  

 

appliance and the installer / service agent a fee calculated on the basis of  $120.00 Call out fee including first 

 

30 min + GST then $45 per 30min, as well as travelling expenses in excess of 25 km each way to rectify such 

 

faults. 

 

Note: 

The Complete Unit Warranty, inclusions, exclusions, terms and conditions are listed on pages 37 to 39 

 

of this manual.  

Содержание Archer IS700

Страница 1: ...PN 200110001S Effective January 2009 Serial Number B D Number Model FS706 Model IS700 Model IS760 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE RERERENCE THIS MANUAL COVERS ALL MODELS FROM IS700 IS714 IS...

Страница 2: ...creen Installation 26 Insert Surround 27 OPERATING INSTRUCTIONS Automatic Humidifier Operation 28 Operating Instructions Checklist 29 30 Lighting Instructions 31 Fan Operation 32 Shutdown Instructions...

Страница 3: ...larification of the instructions contained in this manual please contact Aurora Climate Systems on telephone 03 9795 8895 or facsimile 03 9701 2088 Note As the Archer Gas Log Space Heater you have pur...

Страница 4: ...R GAS LOG SPACE HEATER Note If this appliance is installed by a licensed gas fitter who is not familiar on the installation of the heater we recommend that prior to installing the appliance the instal...

Страница 5: ...REMOVED FROM THIS APPLIANCE DO NOT ENCLOSE THIS APPLIANCE Aurora Climate Systems A B N 43 108 083 987 71 73 Overseas Drive Noble Park VIC 3174 To be installed by an authorised person in accordance wi...

Страница 6: ...Connection Inside 4 3 sided Surround 885 x 742 5 Air Inlet Cover Plate 6 PVC Exhaust Pipe 40mm 7 Flue Exit Point centre line 8 Single Flue Adaptor 9 Single Flexi Flue suit 40mm pipe 11 Bolted Surroun...

Страница 7: ...will void the warranty Note On Single Wall flue pipe installations imitation zero clearance fireplace a minimum of 25mm clearance must be provided at the rear of the heater to enable the heater to ge...

Страница 8: ...ion 0mm D Height Clearance From Unit 15mm 7 Note The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials Aurora Climate Systems recommends that clearan...

Страница 9: ...4 Rear Burner 5 Front Burner NOTE Do not change position of front middle and rear logs as their positions have been preset at the factory Changing log positions will result in faulty gas burner funct...

Страница 10: ...r Latches FIG 1 FIG 2 FIG 3 Left Top Door Tab Right Top Door Tab Properly fitted door shown in Fig 1 Undo Latches when removing door shown in Fig 3 Make sure door tabs can be seen through top of heate...

Страница 11: ...inspect front and rear burner for particle or dust placement on top of burners If any particles or dust is visible on top of the front and rear burners remove particles before placing logs into posit...

Страница 12: ...st the rear at the firebox at the base and at the top B GAS PRESSURE FOR LPG Do not adjust gas burner pressure on LPG Gas burner pressure has been set at factory to required gas burner settings for LP...

Страница 13: ...ipe installation if the unit and flue pipe is installed in line with the manufacturer s installation instructions Refer installation diagram for single flue pipe installations Pages 13 16 17 18 19 20...

Страница 14: ...HEATER No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm PVC Pipe 400mm long 1 Supplied with heater 3 90 PVC Bend 1 Supplied with heater 4 40mm PVC Pipe up to 5 1m Supplied by in...

Страница 15: ...pipe for servicing of the heater Note When connecting 40mm pipe at adaptor end and at cowl end ensure that 40mm pipe is long enough to fit in securely at both ends Failure to do so will cause the flam...

Страница 16: ...place Note Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of app...

Страница 17: ...t be able to be removed easily for servicing Not locked in INTERNAL WALL APPLICATION 1 75mm Cowl 2 Flashing 3 BSP Gas Connection Flexible 4 40mm PVC Pipe Zero Clearance 5 45 PVC Elbow 6 45 PVC Elbow 7...

Страница 18: ...ROM HEATER Note Total installation length in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends 90 Elbow 65mm PVC cowl to suit 40mm PVC flue pipe External Wall Concrete Slab Internal Wall INSTALLATION...

Страница 19: ...in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends Caution To avoid water trap in Flue system 40mm PVC pipe must be supported every 2 metres to avoid PVC pipe sagging and PVC pipe must have fall to...

Страница 20: ...lexible Hose Nylaflow G P Hose Code AH50WAS Supplied with Flue Kit SFA002 Note I D Inside Diameter Flange attached to heater s exhaust fan Supplied and fitted to heater Note If adaptor not fitted dril...

Страница 21: ...ue pipe being forced downwards Supplied by Installer Gas Cowl Supplied in flue kit For safety install gas cock next to appliance Use 1 2 gas loop or part loop in 1 2 copper pipe to allow unit to be re...

Страница 22: ...wo burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater The most common way this button is used is having the Rem...

Страница 23: ...ion Please make sure heater is unplugged when installing Remote Control Please Note The front panel must be opened for this wiring to occur The front panel simply pulls forward no tools required NOTE...

Страница 24: ...met supplied over gas line and insert into back panel IMPORTANT Note The copper gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from it...

Страница 25: ...e Note Gas burner pressure can only be adjusted on high burner setting with both switches medium and low burner in the ON position and flames holding on both burners B represents the test point for co...

Страница 26: ...14 WAY RIBBON TO DISPLAY 1 CONV FAN BLUE 2 TR PRIMARY BLACK TR PRIMARY WHITE 8 1 N C 2 3 1 TRANSFORMER 12V AIR PRESSURE SWITCH REAR BURNER SWITCH PIN 5 FRONT BURNER SWITCH TRANSFORMER 240V PIN 18 PIN...

Страница 27: ...CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MAIN FR...

Страница 28: ...ater FITTING OF LOUVRE Place the louvre in the surround as shown in Diagram A and fasten with the six screws supplied as shown in Diagram B DIAGRAM B FITTING OF SURROUND Place the surround as shown in...

Страница 29: ...utomatic humidifier pump comes on to pump condensate into the stainless steal tray located on the top of the heater the L E D light Page 31 on the front panel will light up and flash for the duration...

Страница 30: ...operating incorrectly causing a safety hazard and will void the manufacturer s warranty of the appliance 6 Check and inspect the appliance for gas leaks In the event of gas leaks cut off the gas supp...

Страница 31: ...se the appliance not to function correctly 15 Check and verify prior to starting up the appliance that all panels are secured in place and that the main door has been locked in position 16 After verif...

Страница 32: ...nd the convection fan will blow warm air from the heater as the heater becomes warmer the medium L E D Item 8 will come on and when the heater has reached its highest operating temperature all three L...

Страница 33: ...te It can take up to approximately 20 30 minutes before the fan speed will change and settle on the next setting The firebox temperature and the outside ambient temperature will regulate how quickly t...

Страница 34: ...IRING The first fire in your heater is part of the paint curing process Your Archer Gas Log Space Heater has been painted with the highest quality heat resistant silicon paint available in the world T...

Страница 35: ...for the heater to do in certain situations Eg Overheating power failure or dips windy conditions pump failure partial or full blockage of flue pipe or no gas All of these operations are monitored by t...

Страница 36: ...ced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently Note If the main convection fan becomes clogged with lint and dust an over temperature sit...

Страница 37: ...y Stainless Steel doors can be cleaned with a metal cleaner that can be used on Stainless Steel Please note Stains or imperfections on plated finishes are not covered under warranty Caution Do not use...

Страница 38: ...verage hereunder this warranty covers all components designated See Conditions Exclusions and Qualifications below for further information on product coverage CONDITIONS EXCLUSIONS AND QUALIFICATIONS...

Страница 39: ...e both ways is to be paid by the owner If Aurora finds a fault with the device they will repair or replace it under the normal warranty terms 1 Year It must also be a recommended device by Aurora Clim...

Страница 40: ...11 Sooting up of heater Note For heaters operating on LPG to avoid sooting up of heater LPG bottle must not be run empty For best practice LPG bottles should be refilled after 75 of fuel has been use...

Страница 41: ...eceiver must be in the remote position for the learn process to occur The burner switches and the red button must all be in the OFF position You will need some sort of pointy object to press the learn...

Страница 42: ...up that you start having difficulty seeing through it this is not normal Nor is having large build up of soot forming on the logs Please note It is normal for some soot to form around the lower and s...

Страница 43: ...ously Check Flue system Check Flue system Call Aurora service Front or Rear Burner L E D light item 5 and 6 not flashing when Front or Rear burner switch is engaged Possible fault in Circuit Board Pan...

Страница 44: ...eration Front or Rear Burner operating L E D Light item 7 8 9 on Front panel display not coming on for Fan Speed Possible fault in thermistor Call Aurora Service L E D light items 7 8 9 on Front Panel...

Страница 45: ...NOTES 44...

Страница 46: ...NOTES 45...

Страница 47: ...NOTES 46...

Страница 48: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING INSTALLATION INSTRUCTIONS TO THE CONSUMER FOR FUTURE REFERENCE DATE OF PURCHASE...

Отзывы: