22
DISPLAY PANEL
T2
T1
P2
RECEIVER
REMOVE LINKS FROM T1,
T2 AND P2 AND PLUG IN LOOM
VIOLET
INSTALL WIRING
LOOMS
LOOM
BLACK
CONNECT THIS WIRE TO THE BODY OF THE
HEATER TO MAKE THE EARTH CONTACT.
FOR EASY ACCESS USE THE SCREW AT THE
BASE OF THE FAN.
WHITE
YELLOW
P2
RED
BUTTON
BLACK
WHITE
PLEASE DO NOT REMOVE THE
BLACK AND WHITE WIRING
FROM THE DISPLAY PANEL
Caution: Please make sure heater is unplugged when installing
Remote Control
Please Note: The front panel must be opened for this wiring to occur.
The front panel simply pulls forward - no tools required.
NOTE: PLEASE KEEP LINKS FROM T1 & T2 INSIDE THE HEATER FOR
FUTURE BRIDGING IF REQUIRED.
J5
FLAT RIBBON CABLE
TO CONTROL BOX
(ALREADY FITTED)
ARCHER GAS LOG SPACE HEATER
INSTALLATION OF THE REMOTE RECEIVER AND
FRONT FLAME DISPLAY BUTTON
Effective 15th April 2008
BLACK
RED
PLACE RECEIVER IN
HEATER BETWEEN PUMP
CONTAINER AND
PRESSURE SWITCH.
RED
BLACK
T2
T1
BLUE
RED
GREEN