The 3-speed main convection fan will cut in automatically approximately 3 to 5 minutes after the heater
has warmed up. Note: The 3-speed main convection fan is automatically controlled and will operate on
three preset speeds. Depending on your burner setting and the surrounding ambient temperature, the
L.E.D lights (Items 7, 8 and 9) for the fan will light up. The bottom L.E.D light (Item 7) is low speed
setting, and middle L.E.D lights (Item 8) is the medium speed setting, the bottom, middle and top L.E.D
lights (Items 7, 8 and 9) is the high-speed setting (both burners on).
Note: The fan will operate totally independent of burner setting - it is controlled by temperature only.
a) Front burner only - low fan speed
b) Rear burner only - medium fan speed
c) Both front and rear burners - high fan speed
On changing the burner setting from high to medium, or from high to low, there will be a delay on the
operating speed of the fan until the firebox has cooled down sufficiently for the fan to change speed.
1.
Note: It can take up to approximately 20-30 minutes before the fan speed will change and settle on
the next setting. The firebox temperature and the outside ambient temperature will regulate how
quickly the fan responds to speed changes.
2
Note: It is quite possible if the room the heater is in starts to reach an ambient of 30°C that the main
convection fan could turn itself on even though the heater or burners are switched off. An example
of this occurring would be in the summer months or from another source of heating. We
recommend if this is occurring that the heater should be turned off at the power point.
FAN OPERATION
HEATER SHUT DOWN INSTRUCTIONS
Turn medium burner switch (Item 2) and low burner switch (Item 1) to the “OFF” position.
Note: The main convection fan in the heater will be operating on and off for up to approximately 45
minutes or more intermittently until the firebox has been cooled down sufficiently for the main fan
to stop operating.
Note: Do not cut main electrical supply to the heater after the heater has been switched off to stop main
fan operating. Main fan will stop operating automatically after the heater has cooled down
sufficiently.