INSTALLATION INSTRUCTIONS
FLUING REQUIREMENTS
Co-Axial Flue Installations
Note: This appliance has only been approved for co-axial flue application if the flue (as
supplied by the manufacturer) is installed to an external wall or external fireplace.
(Refer installation diagram for Co-Axial Flue Installations Pages 14-15-16)
Single Flexi Installations
Note: This appliance has only been approved for single flue pipe installation if the unit and
flue pipe is installed in line with the manufacturer’s installation instructions.
(Refer installation diagram for single flue pipe installations Pages 13-16-17-18-19-20)
CONFIGURATION 1:
Insert Models Pages 13-16-17-18-19-20 - Single Flexi Flue Application.
SINGLE PIPE 40mm ø 5.1 METRES HIGH INCLUDING 2 X 45°
ELBOW, 1 X 90° ELBOW, 1m FLEXIBLE PVC SECTION AND
ONE 75mm COWL.
CONFIGURATION 2:
Insert Models for Installation on External Walls or External Fireplaces
Pages 14-15-16.
CO-AXIAL FLUE INTERNAL PIPE 40MM ø EXTERNAL PIPE
65MM ø BOTH PIPES IN PVC UP TO 1 METRE LENGTH FOR
WALL PENETRATION.