![AUMA SGExC 05.1 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/auma/sgexc-05-1/sgexc-05-1_operation-instructions-manual_3016501064.webp)
Within actuator controls: pollution degree 2
Outside actuator controls (in closed condition): pollution degree 4
Pollution degree
Standard: Two-component iron-mica coating
Finish coating
Standard: AUMA silver-grey (similar to RAL 7037)
Colour
Refer to name plate
Standard:
●
–40 °C to +40 °C
Options:
●
–50 °C to +40 °C
●
–60 °C to +60 °C
Low temperature versions incl. heating system for connection to external power supply 230
V AC or 115 V AC.
Ambient temperature
Open-close duty (operating cycles OPEN - CLOSE - OPEN):
SG 05.1 – SG 07.1: 20,000
SG 10.1: SG 15,000
SG 12.1: 10, 000
Lifetime
Refer to separate technical data
Weight
12.4
Accessories
AUMATIC mounted separately from the actuator, including plug/socket connector. Connecting
cables on request. Recommended for high ambient temperatures, difficult access, or in case
of heavy vibration during service
Wall bracket
1)
COM-AC. An interface cable is required for the standard infra-red programming interface.
Programming software for PC
Cable distance between actuator and AUMATIC max. 100 m. Requires separate data cable for MWG. If actuator and AUMATIC are
separated at a later date, the max. cable length is 10 m.
1)
12.5
Further information
●
ATEX Directive: (94/9/EC)
●
Electromagnetic Compatibility (EMC): (2004/108/EC)
●
Low Voltage Directive: (2006/95/EC)
●
Machinery Directive: (2006/42/EC)
EU Directives
64
SGExC 05.1 – SGExC 12.1 Control unit: electronic (MWG)
Technical data
ACExC 01.1 Non-Intrusive