8.
Fasten actuator with screws [4].
Information: We recommend glueing the screws using sealing material to avoid
contact corrosion.
→
Fasten screws [4] crosswise with a torque according to table:
Table 2:
Tightening torques for screws
Tightening torque T
A
[Nm]
Screws
Thread
Strength class 8.8
11
M6
25
M8
51
M10
87
M12
4.4
Mounting positions of local controls
The mounting position of the local controls is selected according to the order. If, after
mounting the actuator to the valve or the gearbox on site, the local controls are in
an unfavourable position, the mounting position can be changed at a later date. Four
mounting positions are possible.
Figure 8:
Mounting positions A-2 and B-2
Figure 9:
Mounting positions C-2 and D-2
14
SGExC 05.1 – SGExC 12.1 Control unit: electronic (MWG)
Assembly
ACExC 01.1 Non-Intrusive