background image

 

HttpsCertParams (Supported In-Band)   

Displays or sets the attributes used to generate the HTTPS 
certificate. All attributes are optional. C is Country with a fixed 
length of 2 characters. ST is State with a max length of 128 
characters. L is Locality with a max length of 128 characters. O is 
Organization with a max length of 64 characters. OU is 
Organization Unit with a max length of 64 characters. CN is 
Common Name with a max length of 64 characters. If the 
attribute contains spaces or commas, it must be enclosed in 
quotation marks. Changes made to the HTTPS attributes will take 
effect on reboot.   

set HttpsCertParams [C | ST | L | O | OU | CN] [nn...nn]  

get HttpsCertParams 

IdentifyController (Supported In-Band) 

IdentifyController causes the 'Alert' LED to blink to enable 
identification of this system. Disable this option to cancel the 
blinking. 

set IdentifyController [enabled | disabled] 

get IdentifyController 

IdentifyLUN (Supported In-Band) 

Lights the LED(s) of disk drive(s) associated with one or more FC 
LUNs. 

IdentifyLUN [LUN] ... 

Info (Supported In-Band) 

Info displays version numbers and other product information for 
key components. Use the optional 'brief' parameter to show a 
more concise subset of system information. 

Info <brief> 

IPAddress (OEM Configurable, Supported In-Band) 

IPAddress controls the current IP address of any Ethernet port(s). 
If IPDHCP is enabled, then the 'get' command reports the current 
IP address assigned by the network DHCP server, followed by the 
(DHCP) identifier.  

set IPAddress [mp[n] | all] [[xxx.xxx.xxx.xxx] | [[IPv6-compatible 
address] <Prefix length>]] 

get IPAddress [mp[n] |all] 

IPDHCP(OEM Configurable, Supported In-Band) 

IPDHCP allows acquisition of an IP address from a network DHCP 
server. When this option is disabled, the IP address used will be 
specified by the IPAddress CLI command.  

set IPDHCP [mp[n]] [enabled | disabled] 

get IPDHCP [mp[n] | all] 

IPDNSServer (OEM Configurable, Supported In-Band) 

Controls the current DNS Server address. If 

IPDHCP

 is enabled, 

then this value is automatically detected. If 

IPDHCP

is disabled, 

then this value must be manually set (IPv4 only). 

set IPDNSServer [xxx.xxx.xxx.xxx] 

get IPDNSServer 

IPGateway (OEM Configurable, Supported In-Band) 

IPGateway controls the current default gateways used by any 
Ethernet port(s). If IPDHCP i
s enabled, the 'get' command reports 
the current IP gateway assigned by the network DHCP server.  

set IPGateway [mp[n]] [xxx.xxx.xxx.xxx] 

get IPGateway [mp[n] |all] 

IPSubnetMask (OEM Configurable, Supported In-Band) 

IPSubnetMask controls the current subnet masks used by any 
Ethernet port(s). If IPDHCP i
s enabled, the 'get' command reports 
the current IP subnet mask assigned by the network DHCP server.  

set IPSubnetMask [mp[n]] [xxx.xxx.xxx.xxx] 

get IPSubnetMask [mp[n] |all] 

IPV6Prefix (OEM Configurable, Supported In-Band)   

Controls the current IPv6 prefix (1-128) of any Ethernet port(s).   

set IPV6Prefix [mp[n]] [Prefix length]  

get IPV6Prefix [mp[n] | all] 

IsReserved (Supported In-Band) 

IsReserved displays the reservation status of the current services 
session/interface.  

IsReserved 

Licenses  

Displays the system's collection of relevant open source licenses.   

Licenses 

MaxOpTemp (OEM Configurable, Supported In-Band) 

Regulates/displays the maximum enclosure temperature alarm 
of the XstreamCORE in degrees Celsius. If the temperature of the 
XstreamCORE rises above the maximum MaxOpTemp, thermal 
control event handling occurs.  

set MaxOpTemp [75-90] 

get MaxOpTemp 

 

 

Содержание ATTO XstreamCORE FC 7550

Страница 1: ...eamCORE FC 7600 32 Gigabit Dual Fibre Channel to 12 Gigabit SAS intelligent Bridge 2021 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No...

Страница 2: ...bre Channel ports 8 SAS SATA ports 8 Management ports 8 LED indicators 8 Install the XstreamCORE 10 Unpack the packing box verify contents 10 Install the XstreamCORE 10 Installation and Removal of Pow...

Страница 3: ...s 24 Fibre Channel management connection 24 Ethernet Management Connection 25 Serial port connection 25 Appendix B CLI Provides ASCII based Interface 26 CLI Error Messages 27 CLI Summary Reference 27...

Страница 4: ...and four 12Gb x4 SAS connectors Designed to integrate industry leading performance and SAN capabilities into the future generation of storage solutions the XstreamCORE FC 7550 uses a high performance...

Страница 5: ...an external switch SFP Fibre Channel modules included Dual Power Supply Data Mover technology Integrated eCORE Offload Processor SpeedWrite technology improves write performance to tape drives by up t...

Страница 6: ...Network SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232...

Страница 7: ...ibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 16Gb s Green 8Gb s and OFF 4Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activity o...

Страница 8: ...work SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232 ser...

Страница 9: ...Fibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 32Gb s Green 16Gb s and OFF 8Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activit...

Страница 10: ...ces by connecting SAS cables to SAS connector A B C or D 5 Power up the target devices 6 Connect the Ethernet port to your network 7 Connect the AC power cords from the XstreamCORE to the proper AC so...

Страница 11: ...and click on Next XstreamCORE supports the Google Chrome Firefox and Microsoft Edge browsers 14 Click on Reboot Now Wait up to two minutes for the XstreamCORE Ready LED to light indicating the Xstream...

Страница 12: ...rtificate must be SHA256 signed 7 The certificate must have the same attributes as the controller displays in the get HttpsCertParams command see below The file format should appear as follows note th...

Страница 13: ...EXHIBIT 7 CERTIFICATES AND PEM FILE UPLOAD USEFUL FOR SETTING CERTIFICATE ATTRIBUTES OR UPLOADING A PEM FILE IF A SELF SIGNED CERTIFICATE IS NOT DESIRABLE...

Страница 14: ...r Here type in your user name and password and click OK 2 The Status page appears Check default settings to ensure they are appropriate for your configuration Use the individual pages listed on the si...

Страница 15: ...mat Field Name WWN Format Company ID Device ID Byte 0 1 2 3 4 5 6 7 Value 20 00 00 10 86 xx xx xx SAS SATA device mapping SAS SATA devices connected to the XstreamCORE are viewed as Fibre Channel LUNs...

Страница 16: ...The Status page appears 3 From the XstreamVIEW main menu click on the Mapping menu item on the left side of the screen 4 The Mapping page appears If your storage supports SMP the XstreamVIEW System M...

Страница 17: ...ng temperature conditions Power supply status conditions Messages may state that a device is not working a medium has an error or a command has been stopped You may designate which warning level a rec...

Страница 18: ...ications for SNMP functions such as device transitions and device errors 7 Enter a SNMPv3 Username This username and password are separate from the Administrator and Read Only credentials set in the M...

Страница 19: ...error condition that may have been caused by a flaw in the target device s physical medium or its recorded data Power Supply Down Critical Yes Yes A power supply has powered down or was down after un...

Страница 20: ...your XstreamCORE in a standard browser as found in Using XstreamView System Manager click Enter Here type in your user name and password and click OK 2 On the left hand menu click Remote Management 3...

Страница 21: ...on self test sequence Re launch your browser and navigate to the correct IP address Your browser points to the ATO XstreamVIEW welcome screen Type in the user name and password You can access XstreamV...

Страница 22: ...and password Each page can be reached through the menu at the side of each page An image on each page s header shows each port in the product faceplate Each port is clickable and takes you to the app...

Страница 23: ...hichever session issues the first set CLI command can continue to issue set commands while the other sessions can only issue get commands or display information Once a connection is established refer...

Страница 24: ...heck the type of cable cable length limit and number of devices recommended for each port Keep cable lengths as short as possible to ensure the highest signal quality and performance These cable lengt...

Страница 25: ...reamCORE auto detects the Ethernet speed by default It is recommended to use a good quality Cat 5e or better cable Serial port connection The ATTO XstreamCORE supports remote service operations over t...

Страница 26: ...veConfiguration command and a restart of the system before it is implemented The restart can be accomplished as part of the SaveConfiguration command or by using a separate FirmwareRestart command A n...

Страница 27: ...bootfibredelay 15 ClearCLILog ClearCliLog ClearEventLog cleareventlog ControllerLUN enabled get controllerlun ControllerModel get controllermodel ControllerName set controllername Omega6 CoreDumpInfo...

Страница 28: ...utomap HGAddInitiator HGAddInitiator TestGroup 2000001086A6C440 HGAddLUN HGAddLUN TestGroup 5 HGCreate HGCreate TestGroup HGDelete HGDelete all HGDisplay HGDisplay all HGInitiatorName Get HGInitiatorN...

Страница 29: ...onfigfile OpTempWarn 10 set optempwarn 15 Password set password Performance get performance Ping ping mp1 192 42 155 155 ReadOnlyPassword P SSw0rd set readonlypassword ReadOnlyUsername admin get reado...

Страница 30: ...xplanations AutoMap Supported In Band Automatically maps a subset of target devices visible to the firmware to a set of Fibre Channel LUNs All previous maps will be deleted AutoMap BootFibreDelay OEM...

Страница 31: ...mber as seen in DumpEventLog The keyword EXCEPT indicates an exception occurred while processing the command and the keyword RESTART indicates the unit was restarted DumpCLILog NumEntries all DumpConf...

Страница 32: ...annel FW diagnostics core is present in onboard memory FCCorePresent FCDataRate OEM Configurable Supported In Band FCDataRate specifies the Fibre Channel data rate 7550 4 8 16Gb 7600 8 16 32Gb or auto...

Страница 33: ...roup comprised of 32 characters or less only alpha numeric characters dashes and underscores allowed A Host Group will expose specified LUNs to specified initiators To add a LUN to a Host Group use th...

Страница 34: ...M Configurable Supported In Band IPDHCP allows acquisition of an IP address from a network DHCP server When this option is disabled the IP address used will be specified by the IPAddress CLI command s...

Страница 35: ...Username OEM Configurable Supported In Band Specifies the username used for all sessions SSH SFTP and XstreamVIEW Username must be all lowercase 1 to 32 characters long start with an alphabetical char...

Страница 36: ...audRate OEM Configurable Supported In Band SerialPortBaudRate configures the baud rate for the RS 232 serial port The number of data bits per character is fixed at 8 with no parity set SerialPortBaudR...

Страница 37: ...our format If SNTP is enabled and at least one ethernet port is connected to a reachable SNTP time server the time is retrieved from one of the configured SNTP time servers and manual attempts to chan...

Страница 38: ...dio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Compliance with ICES 003 This Class A digit...

Страница 39: ...t and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications...

Страница 40: ...icable of the EMC and Product Safety authorities as indicated below Safety CU 72141224 04 EN 60950 1 CE CSA 60950 1 UL 60950 1 CB IEC60950 1 all national deviations Emissions Immunity FCC Part 15 Clas...

Страница 41: ...ED WARRANTY IS MADE IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED ATTO DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT IMPLIED WARRANTIES CAN...

Отзывы: