ATTO XstreamCORE FC 7600 

The ATTO XstreamCORE FC 7600 is a high-performance intelligent Bridge which adds 32-Gigabit Dual Fibre Channel connectivity to 12-
Gigabit SAS or SATA storage devices.

The XstreamCORE FC 7600 is available in an industry-standard 
1U form factor for easy integration into racks.  

Dimensions 

Width: 

17 inches  

Length: 

11 inches  

Height: 

1.7 inches (1U) 

Weight: 

approximately 10 pounds 

Cooling and airflow 

Operating temperature:

  5-40 °C external 

Humidity: 

10-90% non-condensing 

Air enters from the front and is exhausted out the connector 
side. Ambient air near the inlets should not exceed 40°C. The 
unit automatically stops operation if the temperature goes 
beyond this threshold. 

 

Do not block the enclosure’s vents. The 

XstreamCORE does not allow data transfer if overheating 
occurs. 

Power  

The XstreamCORE FC 7600 features two hot swappable 
power supplies and can be operated with only a single power 
supply inserted. Each power supply has a standard IEC320 
power receptacle and cooling fan. The power requirements of 
the ATTO XstreamCORE FC 7600 plus the power draw of 
other equipment in the rack must not overload the supply 
circuit and or wiring of this rack. 

Input voltage: 

100-240; VAC 1A; 50/60Hz. 

Fibre Channel ports 

The dual independent 32Gb/s Fibre Channel ports connect 
the XstreamCORE FC 7600 to Fibre Channel hosts using 
optical SFP+ connectors and multimode fiber optic cable. 
Make sure all cables are anchored securely at both ends with 
the proper connectors. 

SAS/SATA ports 

The  four  (x4)  12Gb/s  SAS/SATA  connectors  connect  storage 

devices into the Storage Area Network (SAN) using mini-SAS 
HD cable plug connectors.  

Management ports 

Management is provided using the dual 100/1000BASE-T 
Ethernet ports accessible from two right angle RJ-45 
connectors, or the RS-232 serial header console port 
accessible from the serial RJ-45 connector. 

LED indicators 

LED indicators can be viewed from the connector side and the 
front side of the XstreamCORE FC 7600.  

LEDs on the connector side are: 

Power Supplies:

 One LED for each supply. Blue indicates on 

and ready, while blinking Red indicates an unplugged or failed 
supply.  

Ready/Alert:

 On one shared LED a lit green means ready, 

yellow indicates an alert condition. 

Ethernet port connectors: 

A green LED embedded in each 

Ethernet port connector indicates Link/Activity, where green 
solid indicates link, blinking indicates activity and OFF means 
no link is present. A second green LED embedded in each 
Ethernet port connector indicates connection speed, where 
green solid indicates either a 100MbE or 1000MbE 
connection.

  

Fibre Channel port:

 A lit green LED indicates link, and OFF 

means no link. FC Port LEDs are located next to the SFP 
connectors. 

SAS/SATA device:

 SAS LEDs are located below the mini-SAS 

HD connector. A lit green LED indicates a link has been 
established on at least one PHY, and OFF means there are no 
links. 

LEDs on the faceplate are: 

Power Supplies:

 One LED for each supply. Green indicates on 

and ready while amber indicates an unplugged or failed 
supply. 

 If both power supplies are on and both LEDs are 

yellow at the same time, this indicates a bad status connection. 
Status harnesses may not be connected. 

Power:

 A lit green LED indicates power has been turned ON 

to the intelligent Bridge. 

Ready:

 A lit green LED indicates ready and OFF to show not 

ready. 

Alert:

 A lit yellow LED indicates an alert condition. 

Содержание ATTO XstreamCORE FC 7550

Страница 1: ...eamCORE FC 7600 32 Gigabit Dual Fibre Channel to 12 Gigabit SAS intelligent Bridge 2021 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No...

Страница 2: ...bre Channel ports 8 SAS SATA ports 8 Management ports 8 LED indicators 8 Install the XstreamCORE 10 Unpack the packing box verify contents 10 Install the XstreamCORE 10 Installation and Removal of Pow...

Страница 3: ...s 24 Fibre Channel management connection 24 Ethernet Management Connection 25 Serial port connection 25 Appendix B CLI Provides ASCII based Interface 26 CLI Error Messages 27 CLI Summary Reference 27...

Страница 4: ...and four 12Gb x4 SAS connectors Designed to integrate industry leading performance and SAN capabilities into the future generation of storage solutions the XstreamCORE FC 7550 uses a high performance...

Страница 5: ...an external switch SFP Fibre Channel modules included Dual Power Supply Data Mover technology Integrated eCORE Offload Processor SpeedWrite technology improves write performance to tape drives by up t...

Страница 6: ...Network SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232...

Страница 7: ...ibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 16Gb s Green 8Gb s and OFF 4Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activity o...

Страница 8: ...work SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232 ser...

Страница 9: ...Fibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 32Gb s Green 16Gb s and OFF 8Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activit...

Страница 10: ...ces by connecting SAS cables to SAS connector A B C or D 5 Power up the target devices 6 Connect the Ethernet port to your network 7 Connect the AC power cords from the XstreamCORE to the proper AC so...

Страница 11: ...and click on Next XstreamCORE supports the Google Chrome Firefox and Microsoft Edge browsers 14 Click on Reboot Now Wait up to two minutes for the XstreamCORE Ready LED to light indicating the Xstream...

Страница 12: ...rtificate must be SHA256 signed 7 The certificate must have the same attributes as the controller displays in the get HttpsCertParams command see below The file format should appear as follows note th...

Страница 13: ...EXHIBIT 7 CERTIFICATES AND PEM FILE UPLOAD USEFUL FOR SETTING CERTIFICATE ATTRIBUTES OR UPLOADING A PEM FILE IF A SELF SIGNED CERTIFICATE IS NOT DESIRABLE...

Страница 14: ...r Here type in your user name and password and click OK 2 The Status page appears Check default settings to ensure they are appropriate for your configuration Use the individual pages listed on the si...

Страница 15: ...mat Field Name WWN Format Company ID Device ID Byte 0 1 2 3 4 5 6 7 Value 20 00 00 10 86 xx xx xx SAS SATA device mapping SAS SATA devices connected to the XstreamCORE are viewed as Fibre Channel LUNs...

Страница 16: ...The Status page appears 3 From the XstreamVIEW main menu click on the Mapping menu item on the left side of the screen 4 The Mapping page appears If your storage supports SMP the XstreamVIEW System M...

Страница 17: ...ng temperature conditions Power supply status conditions Messages may state that a device is not working a medium has an error or a command has been stopped You may designate which warning level a rec...

Страница 18: ...ications for SNMP functions such as device transitions and device errors 7 Enter a SNMPv3 Username This username and password are separate from the Administrator and Read Only credentials set in the M...

Страница 19: ...error condition that may have been caused by a flaw in the target device s physical medium or its recorded data Power Supply Down Critical Yes Yes A power supply has powered down or was down after un...

Страница 20: ...your XstreamCORE in a standard browser as found in Using XstreamView System Manager click Enter Here type in your user name and password and click OK 2 On the left hand menu click Remote Management 3...

Страница 21: ...on self test sequence Re launch your browser and navigate to the correct IP address Your browser points to the ATO XstreamVIEW welcome screen Type in the user name and password You can access XstreamV...

Страница 22: ...and password Each page can be reached through the menu at the side of each page An image on each page s header shows each port in the product faceplate Each port is clickable and takes you to the app...

Страница 23: ...hichever session issues the first set CLI command can continue to issue set commands while the other sessions can only issue get commands or display information Once a connection is established refer...

Страница 24: ...heck the type of cable cable length limit and number of devices recommended for each port Keep cable lengths as short as possible to ensure the highest signal quality and performance These cable lengt...

Страница 25: ...reamCORE auto detects the Ethernet speed by default It is recommended to use a good quality Cat 5e or better cable Serial port connection The ATTO XstreamCORE supports remote service operations over t...

Страница 26: ...veConfiguration command and a restart of the system before it is implemented The restart can be accomplished as part of the SaveConfiguration command or by using a separate FirmwareRestart command A n...

Страница 27: ...bootfibredelay 15 ClearCLILog ClearCliLog ClearEventLog cleareventlog ControllerLUN enabled get controllerlun ControllerModel get controllermodel ControllerName set controllername Omega6 CoreDumpInfo...

Страница 28: ...utomap HGAddInitiator HGAddInitiator TestGroup 2000001086A6C440 HGAddLUN HGAddLUN TestGroup 5 HGCreate HGCreate TestGroup HGDelete HGDelete all HGDisplay HGDisplay all HGInitiatorName Get HGInitiatorN...

Страница 29: ...onfigfile OpTempWarn 10 set optempwarn 15 Password set password Performance get performance Ping ping mp1 192 42 155 155 ReadOnlyPassword P SSw0rd set readonlypassword ReadOnlyUsername admin get reado...

Страница 30: ...xplanations AutoMap Supported In Band Automatically maps a subset of target devices visible to the firmware to a set of Fibre Channel LUNs All previous maps will be deleted AutoMap BootFibreDelay OEM...

Страница 31: ...mber as seen in DumpEventLog The keyword EXCEPT indicates an exception occurred while processing the command and the keyword RESTART indicates the unit was restarted DumpCLILog NumEntries all DumpConf...

Страница 32: ...annel FW diagnostics core is present in onboard memory FCCorePresent FCDataRate OEM Configurable Supported In Band FCDataRate specifies the Fibre Channel data rate 7550 4 8 16Gb 7600 8 16 32Gb or auto...

Страница 33: ...roup comprised of 32 characters or less only alpha numeric characters dashes and underscores allowed A Host Group will expose specified LUNs to specified initiators To add a LUN to a Host Group use th...

Страница 34: ...M Configurable Supported In Band IPDHCP allows acquisition of an IP address from a network DHCP server When this option is disabled the IP address used will be specified by the IPAddress CLI command s...

Страница 35: ...Username OEM Configurable Supported In Band Specifies the username used for all sessions SSH SFTP and XstreamVIEW Username must be all lowercase 1 to 32 characters long start with an alphabetical char...

Страница 36: ...audRate OEM Configurable Supported In Band SerialPortBaudRate configures the baud rate for the RS 232 serial port The number of data bits per character is fixed at 8 with no parity set SerialPortBaudR...

Страница 37: ...our format If SNTP is enabled and at least one ethernet port is connected to a reachable SNTP time server the time is retrieved from one of the configured SNTP time servers and manual attempts to chan...

Страница 38: ...dio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Compliance with ICES 003 This Class A digit...

Страница 39: ...t and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications...

Страница 40: ...icable of the EMC and Product Safety authorities as indicated below Safety CU 72141224 04 EN 60950 1 CE CSA 60950 1 UL 60950 1 CB IEC60950 1 all national deviations Emissions Immunity FCC Part 15 Clas...

Страница 41: ...ED WARRANTY IS MADE IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED ATTO DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT IMPLIED WARRANTIES CAN...

Отзывы: