E
XHIBIT
9
E
VENTS TRIGGERING
SNMP
NOTIFICATION FOR EXTENDED OR STANDARD TRAP GENERATION
,
SEVERITY LEVEL AND EXPLANATION
Event
Severity
Level
Extended
Traps
disabled
Extended
Traps
enabled
Explanation
Aborted
Command
Warning
No
Yes
A command has been aborted.
Device
Transition
Info
No
Yes
A target device has failed, become offline or come online.
Fibre Channel
Loop Down
Info
Yes
Yes
A loop down event on a Fibre Channel port has occurred.
Fibre Channel
Loop Up
Info
Yes
Yes
A loop up event on a Fibre Channel port has occurred.
Hardware Error Critical
No
Yes
An unrecoverable target device failure.
Illegal Request
Info
No
Yes
An illegal SCSI request has been attempted.
Medium Error
Warning
No
Yes
A command terminated with an error condition that may have been
caused by a flaw in the target device’s physical
medium or its recorded
data.
Power Supply
Down
Critical
Yes
Yes
A power supply has powered down or was down after unit power-up.
Temperature
Info
Yes
Yes
The unit’s internal temperature has increased or decreased to within
standard operating ranges.
Temperature
Warning
Yes
Yes
Unit’s internal temperature has increased to at or within the unit’s
maximum operating temperature less the unit’s temperature warning
offset or decreased to at or within the unit’s minimum operating
temperature plus the unit’s
temperature warning offset.
Temperature
Critical
Yes
Yes
Unit’s internal temperature has increased to at or above the maximum
operating temperature or decreased to at or below the minimum
operating temperature.
Unit Attention
Info
No
Yes
A unit attention condition has occurred.
Unit Power On
Info
Yes
Yes
The unit has been powered up.