![Atop ABLELink SE5408 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/atop/ablelink-se5408/ablelink-se5408_user-manual_3004789009.webp)
User manual Version 1.1
SE5408/SE5416 Multi-port
Serial Server
Copyright © 2010 ATOP Technologies, Inc.
All rights reserved. Designed in Taiwan
- 8 -
Fig 1. SE5416 Front & Rear Panels
Fig 2. SE5408 Front & Rear Panels
Step-by-Step Installation
Plug in the AC power cord to a power outlet and turn on the power switch.
Within one minute, the buzzer shall beep once, and the LCM Display shall display “SE5408/16”
Connect LAN1 to a network switch or to your LAN network with a straight UTP cable, and
connect a host PC to your LAN network with another cable
The LCM Display shall show:
LAN1 default IP: 10.0.50.100
LAN2 default IP: 192.168.1.1
Connect a serial device to one of the serial ports, and make sure a correct cable is used (Pin
assignments for a RS-232 device and for a RS-485 cable are shown in E.3)
14
16
15
13
12
10
9
11
Selectable
RS 232/RS 485/RS 422
8
6
7
5
4
3
2
1
RS 232/RS 485/RS 422
Selectable
NC
COM
NO
Power cord
connection
and switch
LAN Port 1-2
Serial Port 1-8
Serial Port 9-16
Relay
Output
Power cord
connection
and switch
LAN Port 1-2
Serial Port 1-8
Relay
Output
8
6
7
5
4
3
2
1
RS 232/RS 485/RS 422
Selectable
NC
COM
NO