COM Port
To setup a COM port, select Configuration
Æ
Com Port to get the following dialogs to set the COM port to
work in different link modes, TCP Server, TCP Client, and UDP modes.
“TCP Server” Link Mode
The dialog below shows that up to four clients can be assigned. If “Specify IP address” is checked (shown
here), then only the computer with IP address 10.0.55.200 is allowed to access COM1 of the serial server.
Fig 74. TCP Server Mode with up to Four Clients
“TCP Client” Link Mode
In the TCP Client mode, you may specify up to two computer servers for the device to make a TCP
connection. You need to fill in the servers’ IP addresses and servers’ TCP ports.
Fig 75. TCP Client Mode Window: SerialManager
“UDP” Link Mode
In UDP link mode, the device can connection to eight sets of IP addresses. However, you must enter
one set of the addresses at the time (unlike the Web-based configuration where you can enter up to eight
sets at the time). The following two windows show the entry for the first two set of IP address ranges.