![Atop ABLELink SE5408 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/atop/ablelink-se5408/ablelink-se5408_user-manual_3004789010.webp)
User manual Version 1.1
SE5408/SE5416 Multi-port
Serial Server
Copyright © 2010 ATOP Technologies, Inc.
All rights reserved. Designed in Taiwan
- 9 -
Device Size
3. Software
Setup
Factory Default Settings
Note that the Serial Server comes two independent IP addresses for redundant Ethernet interfaces.
Default IP addresses
Interface
Device IP
Subnet mask
Gateway IP
LAN 1
10.0.50.100
255.255.0.0 10.0.0.254
LAN 2
192.168.1.1
255.255.255.0 192.168.1.254
Note: Of the two LANs, only one is active at a time, depending on whether the user’s LAN begins
with 10 (10.x.x.x) or with 192 (192.168.x.x). It is not recommended to assign both LAN
interfaces to the 10.x.x.x, or both to 192.168.x.x network addresses.
Other default settings are shown in the following table:
Parameter
Default Values
Security
User Name
admin
Password
Null
(blank)
Serial