ATLAS North America Proprietary
Sea Scan ARC Scout MKII Operations Manual
1 of 1
Page: 22
Issue: 1.2.4
SCTM2-OPS
Operations Manual
Below is a description of all of the controls with their corresponding HTTP request variables.
Control Name
Request Variable
Value Range
Units
Description
Simple
simple
0 or 1
Enable = 1, Disable = 0
When enabled the
system will reply with
'OK' after receiving the
Sonar Control Panel
request
Enable
dataon
0 or 1
Enable = 1, Disable = 0
Enables/Disables the
transmit & receive
functionality.
Enable Transmit
txon
0 or 1
Enable = 1, Disable = 0
Enables/Disables the
sonar transmit.
Range Lock
rnglock
0 or 1
Enable = 1, Disable = 0
When enabled, locks
the range selection to
match Channel 0's
range setting
Range Channel 0
rngm0
1.0 to 300.0
meters
Sets the slant range of
the sonar.
Range Channel 1
rngm1
1.0 to 300.0
meters
Sets the slant range of
the sonar.
Range Channel 2
N/A
N/A
N/A
This setting is
controlled by the
Channel 0 Range
Setting.
Range Channel 3
N/A
N/A
N/A
This setting is
controlled by the
Channel 1 Range
Setting.
Range Delay Lock
rngdlylock
0 or 1
Enable = 1, Disable = 0
When enabled, locks
the range selection to
match Channel 0's
range delay setting
Range Delay Channel 0 rngdlym0
0.0 to Range
meters
Sets the range delay of
the sonar. Range delay
is the range (starting at
time 0 when data
collection begins) at
which the sonar
hardware starts
sampling sonar data. It
is an offset and its
units are in meters.