ATLAS North America Proprietary
Sea Scan ARC Scout MKII Operations Manual
1 of 1
Page: 10
Issue: 1.2.4
SCTM2-OPS
Operations Manual
CAUTION: Do not connect the MkII Interconnect Cable to any unit until confirming that one
device is configured as a Dual Frequency Master and the second device is configured as a Dual
Frequency Slave. Damage to the device interface may occur if they are not properly configured.
Dual Frequency Slave Configuration
7. Check that everything is connected to the device labeled "Slave", according to the "Sea Scan ARC Scout
MkII Installation Guide", following the single frequency installation instructions. This applies to the
dual frequency configuration to ensure proper device configuration. At a minimum the input power and
network connections need to be connected.
8. To verify proper operation, connect the supplied serial connection to a serial port (via DB9 to USB
converter or direct connection) on a computer. Ensure that the console is connected and that the
terminal program on the PC is set to 115.2 kbps, 8 data bits, no parity, and 1 stop bit. Hand shaking
should be turned off. The console displays many useful start-up and run-time messages.
9. Apply the input and isolated interface power. The serial console will display its start-up message which
includes the version and copyright information. You will now see information related to the network
startup.
Sea Scan ARC Scout Boot Manager
Build: Jun 29 2017 17:15:03
Looking for valid images.
Sea Scan ARC Scout Boot Manager
Build: Jun 29 2017 17:15:03
Looking for valid images.
Loading image #2