ATLAS North America Proprietary
Sea Scan ARC Scout MKII Operations Manual
1 of 1
Page: 29
Issue: 1.2.4
SCTM2-OPS
Operations Manual
Data Name
Variable Name
Units
Value Range
Description
Example Value
Master Unit's
Alarm Flags Array
alarm
N/A
N/A
N/A
{"vhi":0,"ihi":0,"thi":
0}
Master Unit's
Alarm Voltage High
Flag
vhi
N/A
0 or 1
0 - No voltage
alarm
1- Voltage alarm
has been flagged
0
Master Unit's
Alarm Current High
Flag
ihi
N/A
0 or 1
0 - No current
alarm
1- Current alarm
has been flagged
0
Master Unit's
Alarm Temperature
High Flag
thi
N/A
0 or 1
0 - No temperature
alarm
1- Temperature
alarm has been
flagged
0
Slave Unit's Status Slave
N/A
N/A
N/A
N/A
Slave Unit's
Temperature
temp
Degrees Celsius
0.0 to 100.0
Indicates the Slave
unit's current
temperature
27.00
Slave Unit's Voltage
In
vin
VDC
0.0 to 99.9
Indicates the Slave
unit's current input
voltage.
12.10
Slave Unit's Current
In
iin
Amps
0.000 to 9.999
Indicates the Slave
unit's current
drawn.
0.31
Slave Unit's Power
In
pwr
Watts
0.00 to 99.99
Indicates the Slave
unit's current
power
consumption
3.75
Slave Unit's
Warning Flags
Array
warn
N/A
N/A
N/A
{"vhi":0,"thi":0}
Slave Unit's
Warning Voltage
High Flag
vhi
N/A
0 or 1
0 - No voltage
warning
1- Voltage warning
has been flagged
0
Slave Unit's
Warning
Temperature High
Flag
thi
N/A
0 or 1
0 - No temperature
warning
1- Temperature
warning has been
flagged
0
Slave Unit's Alarm
Flags Array
alarm
N/A
N/A
N/A
{"vhi":0,"ihi":0,"thi":
0}
Slave Unit's Alarm
Voltage High Flag
vhi
N/A
0 or 1
0 - No voltage
alarm
0