background image

TECHNICAL SPECIFICATIONS

R

EADINGS ON GAUGES

Gauge

Reading

Unit

Ammeter (P3)

Below max. rating

A

Voltmeter (P4)

Depends upon selector switch

V

Frequencymeter (P5)

Between 52.5 and 50

Hz

Hourmeter (P6)

Adding up

h

Fuel level (P7)

Above 0

Fuel tank full

S

ETTINGS OF SWITCHES

Switch

Function

Activates at

Engine oil pressure

Shut-down

0.5 bar

Engine coolant temperature

Shut-down

105 °C

S

PECIFICATIONS OF THE ENGINE

/

ALTERNATOR

/

UNIT

Reference

Absolute air inlet pressure 

1 bar

values

Air inlet temperature

27 °C

Relative air humidity

60 %

Generator load

Continuous

Limitations

Maximum ambient temperature 

35 °C

without

Maximum altitude

1000 m

derating

Maximum relative air humidity

85 %

Minimum starting temperature

-18 °C

Engine

Type YANMAR

3TNE88–ACG

Rated net output 

12.8 kW

Load speed 

1500 rpm

Electrical system

12 V

Battery

12 V / 66 Ah

Oil circuit capacity

7 l

Cooling circuit capacity

3 + 1 l

Fuel tank capacity

85 l

Fuse F4

10 A

Fuel consumption at full load/no load

2.7/0.8 kg/h

Maximum run time with fuel tank

26 h

Alternator

Type

EC 28 LB–4

Rated net output

15 kVA

Voltage line-to-neutral

230 V

Voltage line-to-line

400 V

Frequency

50 Hz

Speed

1500 rpm

Power factor

0.8

Number of phases

3 + neutral

Winding connections

Star

Insulation armature winding, class

H

Insulation field winding, class

H

Sensitivity of earth leak detector

30 mA

Setting of Q1

20 A

Setting of Q2

16 A

Setting of Q3

16 A

Fuses F1, F2 and F3 for voltmeter selector switch

4 A

Maximum diffusion resistance of earthing rod

1 k

Unit

Dimensions (LxWxH)

1860x811x957mm

Weight net mass

670 kg

Weight wet mass

750 kg

15

I

NSTRUCTION MANUAL

Содержание QAS14 YdS IT

Страница 1: ...sar Glosario Ordlista Glossario Ordliste Ordliste Gloss rio Sanasto 203 Instruction Manual and Parts List for AC Generators QAS14 Yds From following serial number onwards Geldig vanaf volgend serienum...

Страница 2: ...2 QAS14 Yds...

Страница 3: ...t prior notice CONTENTS Safety precautions for generators QAS 4 Leading particulars 5 General description 5 Bodywork 6 Markings 6 Drain plugs and filler caps 6 Control and indicator panel 6 Output ter...

Страница 4: ...breakers to OFF and stop the engine Correct the faulty condition before re starting 10 Never refill fuel while the machine is running Keep fuel away from hot pipes Never smoke while fuelling Do not s...

Страница 5: ...rthing rod 6 Side door access to control and indicator panel 7 Output terminal board 8 Hole for forklift A Alternator AF Air filter C Coupling DFO Drain flexible engine oil DFW Drain flexible cooling...

Страница 6: ...rd and the different earthing connections on the generator DRAIN PLUGS AND FILLER CAPS The drain holes for the engine oil the coolant and the plug for the fuel are located and labelled on the frame th...

Страница 7: ...l failure indicator Indicates that a shutdown appeared L3 Engine preheating system indicator Lights up when the glow plugs in the engine used to facilitate starting are warming up Extinguishes after a...

Страница 8: ...to IEC 364 3 i e one point in the power source directly earthed in this case the neutral The exposed conductive parts of the electric installation must be directly connected to the functional earth If...

Страница 9: ...s as listed in accordance with VDE 0298 installation method C3 Local regulations remain applicable if they are stricter than those proposed below Wire section mm2 2 5 4 6 10 16 25 35 50 70 95 Max curr...

Страница 10: ...sult your local Atlas Copco dealer Check that the warning lamps on the control and indicator panel are out Run the engine for approximately 5 minutes to warm up Check the voltmeter P4 with voltmeter s...

Страница 11: ...eplace Replace Safety cartridge Replace Valve clearance Check adjust Check adjust Check adjust Check adjust Oil fuel and water leaks Check Check Check Check Mechanical links e g fuel solenoid link Gre...

Страница 12: ...probe the outgoing current in the third phase L3 Compare the measured current with the current indicated on ammeter P3 Both readings should be the same 12 QAS14 Yds STORAGE OF THE GENERATOR STORAGE St...

Страница 13: ...ATOR TROUBLE SHOOTING Symptom Alternator does not excite After being excited alternator does not excite Low voltage at no load High voltage at no load Lower than rated voltage at load Higher than rate...

Страница 14: ...e tip clearances The engine runs erratically Fault in fuel control Restriction in a fuel pipe Fault in fuel lift pump Dirty fuel filter element Restriction in air filter cleaner or induction system Ai...

Страница 15: ...ure 18 C Engine Type YANMAR 3TNE88 ACG Rated net output 12 8 kW Load speed 1500 rpm Electrical system 12 V Battery 12 V 66 Ah Oil circuit capacity 7 l Cooling circuit capacity 3 1 l Fuel tank capacity...

Страница 16: ...16 QAS14 Yds...

Страница 17: ...1 2 2 7 6 6 4 4 7 11 11 5 5 1 1 1 1 2 2 12 2 12 a6 b3 c2 c3 c3 a3 P7 G W X10 X14 X14 S2 F4 X16 10A X16 X16 X16 X16 X16 X16 3 H1 X16 X18 X18 X18 X18 X18 X12 X10 X10 X10 X10 X10 X10 K2 K5 5 K5 K1 G1 E1...

Страница 18: ...ndicator Indicateur de niveau de carburant Me instrument f r Kraftstoffstand S2 Emergency stop button Noodstopknop Bouton arr t d urgence Not Aus Taste S7 Low fuel level switch Schakelaar laag brandst...

Страница 19: ...1 2 2 7 6 6 4 4 7 11 11 5 5 1 1 1 1 2 2 12 2 12 a6 b3 c2 c3 c3 a3 P7 G W X10 X14 X14 S2 F4 X16 10A X16 X16 X16 X16 X16 X16 3 H1 X16 X18 X18 X18 X18 X18 X12 X10 X10 X10 X10 X10 X10 K2 K5 5 K5 K1 G1 E1...

Страница 20: ...livello del combustibile Drivstoffm ler S2 Bot n de parada de emergencia Knapp f r n dstopp Pulsante di arresto di emergenza Knapp for sikkerhetsstopp S7 Interruptor bajo nivel de combustible Brytare...

Страница 21: ...1 2 2 7 6 6 4 4 7 11 11 5 5 1 1 1 1 2 2 12 2 12 a6 b3 c2 c3 c3 a3 P7 G W X10 X14 X14 S2 F4 X16 10A X16 X16 X16 X16 X16 X16 3 H1 X16 X18 X18 X18 X18 X18 X12 X10 X10 X10 X10 X10 X10 K2 K5 5 K5 K1 G1 E1...

Страница 22: ...ari S2 N dstopknap fi Bot o de paragem de emerg ncia H t pys ytyskytkin S7 Br ndstofniveaukontakt fi Comutador do n vel baixo de combust vel Alhaisen polttoainem r n merkkivalon kytkin S8 Kontakt h j...

Страница 23: ...N 32A d0 d0 c6 c54 X1 L3 N L2 L1 Q2 16A 30mA 20A Wire size a 1 mm 2 b 1 5 mm 2 c 2 5 mm 2 d 4 mm 2 e 6 mm 2 Colour code 1 brown 2 red 3 orange 4 yellow 5 green 6 blue 7 purple 8 grey 9 white 0 black L...

Страница 24: ...lemme ESPA OL SVENSKA ITALIANO NORSK F1 3 Fusible 4A S kring 4A Fusibile 4A Sikring 4 A G3 Generador Generator Generatore Generator P3 Amper metro 0 30A Amperem tare 0 30A Amperometro 0 30A Amperemete...

Страница 25: ...N 32A d0 d0 c6 c54 X1 L3 N L2 L1 Q2 16A 30mA 20A Wire size a 1 mm 2 b 1 5 mm 2 c 2 5 mm 2 d 4 mm 2 e 6 mm 2 Colour code 1 brown 2 red 3 orange 4 yellow 5 green 6 blue 7 purple 8 grey 9 white 0 black L...

Страница 26: ...ig fi 16 2 fi Disjuntor 16A 2 polar Virrankatkaisin 16 A 2 napainen R3 Udgangsmodstand Resist ncia limitadora Pudotusvastus S4 Voltmeterets omskifterknap fi Comutador selector do volt metro Volttimitt...

Страница 27: ...USE 6 3A BLACK BLACK RED GREEN RED RED BLACK GREEN RED 6 5 4 5 6 4 3 2 1 0 B 3 2 1 0 B P GREEN RED 180 CIRCUIT DIAGRAM DIAGRAMMA DEL CIRCUITO ELEKTRISCH SCHEMA KRETSSKJEMA SCHEMA DE CIRCUIT STR MDIAGR...

Отзывы: