Atlantic TidalWave TT1500 Скачать руководство пользователя страница 5

5

Cleaning

TidalWave TT-series pumps require periodic cleaning of the stainless steel cooling screen, 
rotor and rotor chamber. Please follow the directions below for proper cleaning procedures:

•  Unlock the latches on either side of the pre-filter by pulling outward from the pump 
 

handle. Slide the pre-filter off to expose the volute.

•  Remove the volute by rotating counterclockwise one quarter turn while pulling lightly  
 

outward from the pump body. The TT9000 will require the removal of five screws to  

 

remove the volute.

•  Inspect the intake O-ring for nicks or breaks.

•  Inspect the impeller and remove any debris that may be present.

•  A stainless steel screen located behind the impeller draws water in to cool the rotor. If  
 

the screen becomes blocked the pump may overheat. Inspect the screen and remove any  

 

accumulated debris. 

•  Spin the impeller. If the impeller is difficult to turn, feels “gritty”, or a grinding noise is  
 

evident in the rotor chamber, remove the rotor as per the instructions below. 

 

 

 

 

 

 

 

 

Removing the rotor

The rotor must be unlocked using the built-in wrench located on the bottom of the pre-filter 
before it can be removed from the rotor chamber. Slide the impeller wrench behind the  
impeller and engage two of the locking posts located on the face of the rotor. Push the 
wrench tightly against the rotor face and rotate counterclockwise one quarter turn. Once 
unlocked, remove the rotor by pulling the impeller outward from the pump body.

•  Inspect the stainless steel rotor and the rotor chamber for built up debris. Loose debris  
 

can be flushed out with clean water. Often in hard water, well water  

 

or pond-free applications, debris may appear as a crusty film  

 

around the rotor and in the rotor chamber.  

 

Remove this film using a scrub brush  

 

and white vinegar. 

•  Slide the rotor into the rotor  
 

chamber and lock it in place  

 

by rotating clockwise  

 

one quarter turn.

•  Attach the volute by  
 

applying pressure and  

 

rotating clockwise  

 

one quarter turn.

•  Replace the pre-filter  
 

and lock the latches.

Содержание TidalWave TT1500

Страница 1: ...Pumps Couvre les pompes Comprende las siguientes bombas TT1500 TT2000 TT3000 TT4000 TT5000 TT6000 TT9000 1 877 80 PONDS www atlanticwatergardens com Operating Manual Manuel d utilisation Manual de op...

Страница 2: ...wer plug and the AC outlet receptacle are protected and away from water or pump discharge hose to prevent accidental electric shock or short circuit Always operate the pump completely submerged in wat...

Страница 3: ...be used if the electrical supply cable is damaged in any way If a cable with damaged insulation is submerged in water there is danger of water seeping into the pump motor and causing a short The elect...

Страница 4: ...rotor If the screen becomes blocked the pump may overheat Inspect the screen and remove any accumulated debris Inspect the impeller The impeller should spin freely If the impeller feels tight or grit...

Страница 5: ...r a grinding noise is evident in the rotor chamber remove the rotor as per the instructions below Removing the rotor The rotor must be unlocked using the built in wrench located on the bottom of the p...

Страница 6: ...Intake is blocked Impeller needs cleaned Remove debris from the pump intake Refer to page 5 for cleaning instructions Diminished flow rate or no water flow Impeller needs cleaned Refer to page 5 for c...

Страница 7: ...ur sont prot g es et loin de l eau ou du tuyau de d charge de la pompe afin d viter une commotion lectrique ou un court circuit accidentels Faites toujours fonctionner la pompe compl tement immerg e d...

Страница 8: ...oit pas tre utilis e si le c ble d alimentation lectrique est endommag d une quelconque fa on Si un c ble avec une isolation endommag e est plong dans l eau il y a un danger que de l eau ne s infiltre...

Страница 9: ...la turbine fait passer l eau pour refroidir le rotor Si ce tamis devient obstru la pompe peut passer en surchauffe Inspectez le tamis et liminez tous les ventuels d bris accumul s Inspectez le rotor L...

Страница 10: ...difficult s tourner cherchez l vidence de granules ou d un bruit de broyage au niveau de la chambre du rotor puis d posez le rotor selon les instructions qui suivent D pose du rotor Le rotor doit tre...

Страница 11: ...emplacez le disjoncteur diff rentiel L admission est obstru e le rotor a besoin d tre nettoy D gagez les d bris de l entr e de la pompe R f rez vous aux instructions de nettoyage en page 10 D bit en d...

Страница 12: ...CA est n protegidos y alejados del agua o de la manguera de descarga de la bomba a fin de prevenir choques el ctricos o cortocircuitos accidentales Haga funcionar la bomba siempre sumergida por comple...

Страница 13: ...nos en el agua en que est sumergida la bomba Fig 2 La bomba sumergible no debe utilizarse si el cable de alimentaci n el ctrica tiene alg n tipo de da o Si un cable con el aislamiento da ado se sumerg...

Страница 14: ...nfriar el rotor Si la rejilla se obstruye la bomba se podr a calentar excesivamente Inspeccione la rejilla y remueva cualquier suciedad acumulada Inspeccione el impulsor El impulsor debe girar libreme...

Страница 15: ...n ruido de molienda es evidente en la c mara del rotor remueva el rotor seg n las siguientes instrucciones Remueva el rotor El rotor se debe desasegurar utilizando la llave incorporada ubicada en la p...

Страница 16: ...ctrica Revise o reemplace el interruptor de falla a tierra GFCI La admisi n est bloqueada El impulsor necesita limpieza Elimine los desperdicios de la admisi n de la bomba Para ver las instrucciones d...

Отзывы: