Atlantic TidalWave TT1500 Скачать руководство пользователя страница 2

Prior to Operation and Installation

•  When the pump is delivered, first perform the following checks:

 

•  Check for any damage to pump and power cable that may have occurred  

 

 

during shipment.

 

•  Check the model number to make sure it is the product that was ordered and verify  

 

 

the voltage and frequency are correct.

Caution

•  DO NOT operate this product under any conditions other than those for which it is  
 

specified. Failure to observe this precaution can lead to electrical shock, electrical  

 

leakage, fire, water leakage or other problems.

•   The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage  
 

within 110-120 volt 60 Hz.

•  Never place your hand or any object in or near the inlet opening while this equipment is  
 

operating. If pump inlet is clogged, always turn off the power supply and wait until the  

 

motor is completely stopped before attempting to remove any clogged material.

•  Please make sure that the power plug and the AC outlet receptacle are protected and away  
 

from water or pump discharge hose to prevent accidental electric shock or short circuit.

•  Always operate the pump completely submerged in water.

•  Avoid dry operation, which will not only lower performance but can cause the pump to  
 

overheat/malfunction, leading to electrical leakage, shock or premature failure.

•  Always turn off power or unplug the pump prior to performing any maintenance or  
 

placing your hands into the water.

• 

CAUTION:

   

 

THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.

•  

CAUTION:

  

 

THIS PUMP HAS BEEN EVALUATED FOR USE IN  WATER ONLY.

Introduction

Thank you for selecting the TidalWave TT1500, TT2000, TT3000, TT4000, TT5000, TT6000  
or TT9000 pump. Before using this pump please take a moment to review this manual.

To avoid an accident do not use the pump in any way other than as described in this 
manual. Please note the manufacturer cannot be responsible for accidents arising because 
the product was not used as prescribed. After reading this manual keep it as a reference in 
case questions arise during use.

2

Flow 
Chart: 
(GPH)

Содержание TidalWave TT1500

Страница 1: ...Pumps Couvre les pompes Comprende las siguientes bombas TT1500 TT2000 TT3000 TT4000 TT5000 TT6000 TT9000 1 877 80 PONDS www atlanticwatergardens com Operating Manual Manuel d utilisation Manual de op...

Страница 2: ...wer plug and the AC outlet receptacle are protected and away from water or pump discharge hose to prevent accidental electric shock or short circuit Always operate the pump completely submerged in wat...

Страница 3: ...be used if the electrical supply cable is damaged in any way If a cable with damaged insulation is submerged in water there is danger of water seeping into the pump motor and causing a short The elect...

Страница 4: ...rotor If the screen becomes blocked the pump may overheat Inspect the screen and remove any accumulated debris Inspect the impeller The impeller should spin freely If the impeller feels tight or grit...

Страница 5: ...r a grinding noise is evident in the rotor chamber remove the rotor as per the instructions below Removing the rotor The rotor must be unlocked using the built in wrench located on the bottom of the p...

Страница 6: ...Intake is blocked Impeller needs cleaned Remove debris from the pump intake Refer to page 5 for cleaning instructions Diminished flow rate or no water flow Impeller needs cleaned Refer to page 5 for c...

Страница 7: ...ur sont prot g es et loin de l eau ou du tuyau de d charge de la pompe afin d viter une commotion lectrique ou un court circuit accidentels Faites toujours fonctionner la pompe compl tement immerg e d...

Страница 8: ...oit pas tre utilis e si le c ble d alimentation lectrique est endommag d une quelconque fa on Si un c ble avec une isolation endommag e est plong dans l eau il y a un danger que de l eau ne s infiltre...

Страница 9: ...la turbine fait passer l eau pour refroidir le rotor Si ce tamis devient obstru la pompe peut passer en surchauffe Inspectez le tamis et liminez tous les ventuels d bris accumul s Inspectez le rotor L...

Страница 10: ...difficult s tourner cherchez l vidence de granules ou d un bruit de broyage au niveau de la chambre du rotor puis d posez le rotor selon les instructions qui suivent D pose du rotor Le rotor doit tre...

Страница 11: ...emplacez le disjoncteur diff rentiel L admission est obstru e le rotor a besoin d tre nettoy D gagez les d bris de l entr e de la pompe R f rez vous aux instructions de nettoyage en page 10 D bit en d...

Страница 12: ...CA est n protegidos y alejados del agua o de la manguera de descarga de la bomba a fin de prevenir choques el ctricos o cortocircuitos accidentales Haga funcionar la bomba siempre sumergida por comple...

Страница 13: ...nos en el agua en que est sumergida la bomba Fig 2 La bomba sumergible no debe utilizarse si el cable de alimentaci n el ctrica tiene alg n tipo de da o Si un cable con el aislamiento da ado se sumerg...

Страница 14: ...nfriar el rotor Si la rejilla se obstruye la bomba se podr a calentar excesivamente Inspeccione la rejilla y remueva cualquier suciedad acumulada Inspeccione el impulsor El impulsor debe girar libreme...

Страница 15: ...n ruido de molienda es evidente en la c mara del rotor remueva el rotor seg n las siguientes instrucciones Remueva el rotor El rotor se debe desasegurar utilizando la llave incorporada ubicada en la p...

Страница 16: ...ctrica Revise o reemplace el interruptor de falla a tierra GFCI La admisi n est bloqueada El impulsor necesita limpieza Elimine los desperdicios de la admisi n de la bomba Para ver las instrucciones d...

Отзывы: