Chapter 3. Front Panel Operation
57
EDID Mode options are:
3. Press
Menu
to return to the Menu page.
4. Press
Cancel
to return to the previous step without change.
Note:
The default EDID setting is Default.
CEC
To configure the CEC settings, do the following:
1. From the Operation page, press pushbutton
2
to access the CEC page:
EDID Option
Description
1:
Default
ATEN’s default EDID data is passed to all video sources by
default when the system is powered on.
2:
Port1
EDID data read from port 1 is passed to all video sources. The
system will enforce the Default EDID setting if port 1 is not
occupied.
3:
Remix
This mode reads the EDID data from all connected displays and
generates the optimum EDID for all video sources. The system
will not re-generate a new EDID when a new device is plugged in,
unless triggered by a pushbutton or command.
4:
Customized
This mode features an EDID Wizard that allows user-defined
EDID configurations for optimum output. See
1: EDID Mode: Default
2: CEC
3: OSD
4: Output Status
↓: Next