Chapter 6. CLI Commands
165
Alert Command
To trigger a warning when issues arise for a specific input port, use the
following command:
C Input + C [Enter]
1. For example, to enable the basic Alert function for input port 1, type:
alert i01 m1 [enter]
The following tables show the possible values for the
Alert
command:
Note:
Each command string can be separated with a space.
The following table lists the available Alert commands:
Command
Description
alert
Alert command
Input
Description
i
Input command
Port number
Description
yy
01-32 port
Control
Description
off
Disable Alert (default)
m1
Show basic Alert (flashing border)
m2
Show detailed Alert (flashing border
and port information)
Comman
d
Input
Com
-
mand
Input Port
Control
Enter
Description
alert
i
yy
off
[Enter]
Alert off for input port yy
(yy:01~32)
alert
i
yy
m1
[Enter]
Basic Alert on for input port yy
(yy:01~32)
alert
i
yy
m2
[Enter]
Detailed Alert on for input port
yy
(yy:01~32)
Содержание VanCryst VM3200
Страница 1: ...32 x 32 Modular Matrix Switch VM3200 VM3250 User Manual www aten com ...
Страница 16: ...VM3200 VM3250 User Manual xvi This Page Intentionally Left Blank ...
Страница 58: ...VM3200 VM3250 User Manual 42 This Page Intentionally Left Blank ...
Страница 82: ...VM3200 VM3250 User Manual 66 This Page Intentionally Left Blank ...
Страница 88: ...VM3200 VM3250 User Manual 72 5 Click Save This profile is added to the Profile List ...
Страница 184: ...VM3200 VM3250 User Manual 168 This Page Intentionally Left Blank ...