User replaceable parts
T3-OPX User Guide
79
3.
Insert the Torx screwdriver and locate the service tray screw (should be straight in).
Warning:
Moving the service tray will uncap the printhead. Be careful with this
operation.
Fuse power inlet replacement
The fuse in the power inlet can be replaced by the operator.
Fuse replacement process
Warning:
Remove power cord cable before continuing.
1.
Open the fuse lid on the power inlet carefully using a flat head screw driver. The lid is
marked with a white sticker and a description (T3.15A).
2.
Remove the fuse.
Part Number
Description
15140120
FUSE T3.15A
Содержание TrojanLabel T3-OPX