Edge sensor (TOF control)
T3-OPX User Guide
75
Adjusting the sensor to the media
1.
Move the print unit to a height position where the media can pass underneath. It does not
need to 100% set to the height but within 10mm above the media.
2.
Adjust the sensor to ensure that the switching threshold is not activated. This means that
the green value (switching threshold), should be less than the actual value. Use the step
buttons (9) and (10) to adjust the value. Remember that the sensor should not be over
the belts, but over the black surface on the table.
3.
Place the media under the sensor. The led indicator (7) should light up orange. When the
media is removed then the led indicator shall switch off. Use the step buttons to adjust
the sensitivity up or down. The threshold value is instantly saved.
9
step pushbutton > (manual switching threshold: higher/next function
parameter)
10
step pushbutton < (manual switching threshold: lower/previous
function parameter)
11
Mode/Enter-button
12
Teach-in button
#
Description