![Astria Fireplaces Arcadia18MN Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/astria-fireplaces/arcadia18mn/arcadia18mn_installation-and-operation-instructions-manual_2990879009.webp)
www.Astria.US.com
126896-01A
9
CAUTION: Make sure exter
-
nal regulator has been installed
between propane/LP supply and
log set. See guidelines under
Connecting to Gas Supply
,
page 7.
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping system.
Pressures in excess of 1/2 psig (3.5 kPa) will
damage the log set's regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff
valve to gas supply. Check reconnected fit
-
tings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 8).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
INSTALLATION
Continued
Check your building codes for any special re
-
quirements for locating equipment shutoff valve
to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged log set valves.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment trap
(not supplied with log set) in supply line as shown
in Figure 7, page 8. Locate sediment trap where
it is within reach for cleaning. Install in piping
system between fuel supply and the log set. Locate
sediment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture and con
-
taminants. This keeps them from going into appli
-
ance controls. If sediment trap is not installed or is
installed wrong, the log set may not run properly.
CAUTION: Avoid damage to
gas control. Hold gas control
with wrench when connecting it
to gas piping and/or fittings.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
Figure 8 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Содержание Arcadia18MN
Страница 26: ...NOTES...
Страница 27: ...NOTES...
Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...