Astria Fireplaces Arcadia18MN Скачать руководство пользователя страница 7

www.Astria.US.com

126896-01A

7

INSTALLATION

Continued

Damper

Clamp

Damper

Damper

Damper

Clamp

Masonry Fireplace

Manufactured 

Fireplace

Figure 4 - Attaching Damper Clamp

The minimum flue sizes shown in Figure 3, page 

6, are based on a 6' chimney height using round 

pipe. Your  minimum  flue  size  will  vary  based 

on input rate and chimney height. Refer to the 

National Fuel Gas Code ANSI Z223.1/NFPA 54, 

Section 6.6

 for details.

INSTALLING DAMPER CLAMP

Secure damper stop clamp to edge of damper as 

shown in Figure 4. I for any reason this clamp 

doesn't work on your fireplace, another suitable 

clamp  or  permanent  stop  must  be  installed  or 

damper blade must be removed.

INSTALLING LOG SET ASSEMBLY

  CAUTION:  Do  not  remove 

the data plates attached to the 

log set base assembly. The data 

plates contain important war-

ranty and safety information.

 WARNING: If installing in a 

sunken  fireplace,  special  care 

is needed. You must raise the 

fireplace floor to allow access to 

log set control panel. This will in-

sure adequate air flow and guard 

against sooting and controls 

being damaged. Raise fireplace 

floor with noncombustible mate

-

rial. Make sure material is secure.

 CAUTION: Do not pick up the 

log set assembly by the logs. 

This could damage log set. Only 

handle base assembly by grates.

IMPORTANT:

 Make sure appliance is level. If 

the log set is not level, it will not work properly.

Installation Items Needed

•  control cover kit (provided with log set)
•  approved flexible gas hose (provided) (if al

-

lowed by local codes) 

•  sealant  (resistant  to  propane/LP  gas,  not 

provided)

•  pipe wrench

Note:

 Install optional remote control accessories 

(see 

Accessories

,  page  19)  before  installing 

gas log set.
1.  Apply pipe joint sealant lightly to male threads 

of gas fitting (not provided). Connect approved 

flexible gas hose to inlet side of gas control (see 

Figure 5). 

IMPORTANT:

 Hold gas fitting with 

wrench when connecting flexible gas hose.

2.  Position log set assembly in fireplace.
3.  Connect  to  gas  supply.  See 

Connecting to 

Gas Supply

.

CONNECTING TO GAS SUPPLY

 WARNING: This appliance 

requires a 3/8" NPT (National 

Pipe Thread) inlet connection to 

the pressure regulator.

 WARNING: A qualified ser

-

vice person must connect the 

log set to gas supply. Follow all 

local codes.

Gas Control

Flexible 

Gas Hose 

(if allowed 

by local 

codes)

Figure 5 - Attaching Flexible Gas Hose to 

Log set Gas Regulator

Содержание Arcadia18MN

Страница 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Страница 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Страница 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Страница 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Страница 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Страница 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Страница 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Страница 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Страница 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Страница 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Страница 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Страница 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Страница 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Страница 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Страница 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Страница 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Страница 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Страница 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Страница 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Страница 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Страница 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Страница 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Страница 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Страница 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Страница 26: ...NOTES...

Страница 27: ...NOTES...

Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...

Отзывы: