SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  log set will not produce specified heat
•  propane/LP gas supply may be low
You  may  feel  your  gas  pressure  is  too  low.  If 

so, contact your local propane/LP or natural gas 

supplier.

TECHNICAL SERVICE

You may have further questions about installation, 

operation, or troubleshooting. If so, contact IN

-

NOVATIVE HEARTH PRODUCTS’s Technical 

Service  Department  at  1-800-655-2008. When 

calling please have your model and serial numbers 

of your appliance ready.
You can also visit our technical services web site 

at 

www.IHP.US.com

.

REPLACEMENT PARTS

Note:

 Use only original replacement parts. This 

will  protect  your  warranty  coverage  for  parts 

replaced under warranty. 

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they 

can’t supply original replacement part(s), call IN

-

NOVATIVE HEARTH PRODUCTS’s Technical 

Service Department at 1-800-655-2008.
When calling, have ready
•  your name
•  your address
•  model and serial numbers of your appliance 
•  how appliance was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 

factory.

ACCESSORIES

Purchase these log set accessories from your local 

dealer. If they can not supply these accessories, 

call  INNOVATIVE  HEARTH  PRODUCTS  at 

1-800-655-2008 for referral information. You can 

also write to the address listed on the back page 

of this manual.

RECEIVER AND HAND-HELD 

REMOTE CONTROL KIT - 112806-01

(Not Shown)

For PDG models. 

Allows the gas log to be turned 

on and off by using a hand-held remote control. 

This remote comes installed in BTB models. 

REMOTE CONTROL RECEIVER 

BRACKET - 112806-02
(Not Shown)

For PDG models only.

 Used for mounting remote 

control receiver to unit base. 

WALL-MOUNT  ON/OFF  SWITCH 

GWMS2 

(Not Shown)

For all models.

 Allows the gas log to be turned on 

and off with a wall switch. This switch is included 

with al models.

DAMPER CLAMP - GA6080

(Not Shown)

For all models.

 Permanently opens chimney flue 

damper  for  vented  operation. This  is  included 

with all models.

LAVA ROCK - GA6060

(Not Shown)

For all models.

 Order when additional rock is 

desired. (1.8 lb. bag)

FLOOR MEDIA KIT - VTA-LS5-1

(Not Shown)

For all models.

 Order when additional logs is 

desired. (5 pieces)

FLOOR MEDIA KIT - VTA-LS5-2

(Not Shown)

For all models.

 Order when additional logs is 

desired. (5 pieces)

Содержание Arcadia18MN

Страница 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Страница 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Страница 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Страница 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Страница 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Страница 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Страница 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Страница 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Страница 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Страница 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Страница 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Страница 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Страница 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Страница 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Страница 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Страница 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Страница 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Страница 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Страница 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Страница 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Страница 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Страница 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Страница 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Страница 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Страница 26: ...NOTES...

Страница 27: ...NOTES...

Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...

Отзывы: