Astria Fireplaces Arcadia18MN Скачать руководство пользователя страница 11

www.Astria.US.com

126896-01A

11

OPERATING APPLIANCE

Continued

5.  Wait five (5) minutes to clear out any gas. 

Then smell for gas, including near the floor. 

If you smell gas, STOP! Follow “B” in the 

safety information, page10. If you don’t 

smell gas, go to the next step.

6.  Press in and turn control knob counter-

clockwise 

 to the PILOT position. 

Press in control knob for five (5) seconds 

(see Figure 11). 

 

Note

: You may be running this log set for 

the first time after hooking up to gas sup

-

ply. If so, the control knob may need to be 

pressed in for 30 seconds or more. This will 

allow air to bleed from the gas system.

7.  With control knob pressed in, press ignitor 

button. This will light pilot. The pilot is at-

tached to the front burner. If needed, keep 

pressing ignitor button until pilot lights.

 

Note:

 If pilot does not stay lit, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

8.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

• If control knob does not pop out when 

released, contact a qualified service person 

or gas supplier for repairs.

 

Note:

 If pilot goes out, repeat steps 4 

through 8.

9.  Slightly push in and turn control knob coun-

terclockwise 

 to the ON position.

10.  Wait one minute and switch selector switch 

to the ON position to light burners. 

11.  Set  flame  adjustment  knob  to  any  level 

between HI and LO.

 CAUTION: Do not try to ad

-

just heating levels by using the 

equipment shutoff valve.

Figure 11 - Control Knob and Ignitor 

Button Locations

LO

IH

OF

F

PILOT ON

AUTO

OFF

ON

Control Knob

Ignitor Button

Flame Adjustment Knob

Selector Switch

LIGHTING 

INSTRUCTIONS

NOTICE: During initial operation 

of new log set, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres

-

ent. Open damper or window to 

vent smell. This will only last a 

few hours. 

 WARNING: Damper handle 

will be hot if appliance has been 

running.

 CAUTION: A mild gas flash 

within 10 seconds is normal 

during shutdown of this log set. 

Remain clear of the hearth area 

for the entire shutdown process 

to avoid possible injury.

NOTICE:  During  initial  opera

-

tion of new the log set, metallic 

components may emit an odor as 

paint and assembly compounds 

are heated and cure. Be sure 

to provide adequate fresh air if 

odors are detected. 

1.  STOP! Read the safety information on 

page 10.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Set selector switch in the OFF position.
4.  Turn motor knob clockwise 

 to the 

OFF position.

 WARNING: Burners will 

come on automatically within 

one minute when the selector 

switch is in the ON position after 

the pilot is lit.

Содержание Arcadia18MN

Страница 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Страница 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Страница 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Страница 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Страница 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Страница 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Страница 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Страница 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Страница 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Страница 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Страница 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Страница 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Страница 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Страница 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Страница 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Страница 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Страница 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Страница 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Страница 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Страница 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Страница 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Страница 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Страница 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...