![Astria Fireplaces Arcadia18MN Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/astria-fireplaces/arcadia18mn/arcadia18mn_installation-and-operation-instructions-manual_2990879010.webp)
www.Astria.US.com
1
26896
-01A
10
INSTALLATION
Continued
Figure 10 - Checking Gas Joints for
Propane/LP Gas
Control Valve
Location
Propane/LP
Supply Tank
Equipment Shutoff Valve
Figure 9 - Checking Gas Joints for
Natural Gas
Gas Meter
Equipment Shutoff Valve
Control Valve Location
OPERATING LOG SET
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open
when operating unit.
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualified service tech
-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
3. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP sup
-
ply to equipment shutoff valve for propane/LP
(see Figure 9 or 10). Apply noncorrosive leak
detection fluid to all joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 8,
page 9).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of the appliance is in
the OFF position.
4. Check all joints from equipment shutoff valve
to control valve (see Figure 9 or 10). Apply
noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light log set (see
Operating Appliance
).
Check all other internal joints for leaks.
7. Turn off log set (see
To Turn Off Gas to Ap-
pliance
, page 10).
Содержание Arcadia18MN
Страница 26: ...NOTES...
Страница 27: ...NOTES...
Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...