Astria Fireplaces Arcadia18MN Скачать руководство пользователя страница 3

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

  WARNING:  Keep  flue  open 

when operating unit.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op-

erate or service this log set. 

Improper use of this appliance 

can cause serious injury or 

death  from  burns,  fire,  explo

-

sion, electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning:

 Early signs of carbon 

monoxide poisoning resemble the flu, with head

-

aches, dizziness or nausea. If you have these signs, 

the log set may not be working properly. 

Get fresh 

air at once!

 Have the appliance serviced. Some 

people are more affected by carbon monoxide than 

others. These  include  pregnant  women,  people 

with heart or lung disease or anemia, those under 

the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas:

 Natural and propane/

LP gases are odorless. An odor-making agent is 

added to these gases. The odor helps you detect 

a gas leak. However, the odor added to the gas 

can  fade.  Gas  may  be  present  even  though  no 

odor exists.
Make certain you read and understand all warn

-

ings. Keep this manual for reference. It is your 

guide to safe and proper operation of this log set.

 WARNING: Any change to 

this log set or its controls can 

be dangerous.

SAFETY INFORMATION

Continued

 WARNING: Do not use a 

blower insert, heat exchanger 

insert or other accessory not ap-

proved for use with this log set.

 WARNING: Do not allow fans 

to blow directly into the log set. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create drafts that alter burner 

flame  patterns. Altered  burner 

patterns can cause sooting.

 WARNING: Do not place 

log scraps or lava rocks on 

burner.

Due to high temperatures, the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable material on or near 

the appliance. Never place any 

objects on this log set.

Log set base assembly becomes 

very hot when running the appli-

ance. Keep children and adults 

away from hot surface to avoid 

burns or clothing ignition. The 

appliance will remain hot for 

a time after shutdown. Allow 

surface to cool before touching.

Carefully supervise young chil-

dren when they are in the room 

with the appliance. When using 

the hand-held remote accessory, 

keep selector switch in the OFF 

position to prevent children from 

turning on burners with remote.

Содержание Arcadia18MN

Страница 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Страница 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Страница 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Страница 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Страница 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Страница 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Страница 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Страница 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Страница 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Страница 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Страница 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Страница 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Страница 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Страница 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Страница 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Страница 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Страница 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Страница 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Страница 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Страница 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Страница 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Страница 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Страница 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Страница 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Страница 26: ...NOTES...

Страница 27: ...NOTES...

Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...

Отзывы: