INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in 

a solid-fuel burning masonry or UL127 factory-built 

fireplace, constructed of noncombustible material 

and connected to a working flue. (See page 6 for 

minimum flue opening.)

WARNING: This is a gas-fired heater. It uses air (oxy-

gen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be 

provided. Refer to the National Fual Gas Codes, ANSI 

Z233.1/NFPA 54, Section 5.3 for Combustion and 

Ventilation.

 

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

• 

 Do not try to light any appliance. 

• 

 Do not touch any electrical switch; do not use any phone in your building. 

• 

 Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installation and Operation Instructions

Astria

TM

 Vented Gas Log Decorative Appliance

P/N 126896-01   Rev.A   02/2014

PFS

®

US

Models

Arcadia18MN
Arcadia18MP

Arcadia24MN
Arcadia24MP

P126896-01

Содержание Arcadia18MN

Страница 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Страница 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Страница 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Страница 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Страница 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Страница 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Страница 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Страница 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Страница 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Страница 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Страница 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Страница 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Страница 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Страница 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Страница 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Страница 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Страница 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Страница 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Страница 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Страница 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Страница 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Страница 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Страница 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Страница 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Страница 26: ...NOTES...

Страница 27: ...NOTES...

Страница 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...

Отзывы: